3.4.4 Switch Settings

On the top face of the module, there are switches for selecting the operation.
(1)
Encoder A-phase/B-phase method selection DIP SW1-1, 2
Open collector
Differential
Table 3.4-3 DIP SW for encoder A-phase/B-phase method selection
(2)
Encoder Z-phase method selection DIP SW1-3
Open collector
Differential
Table 3.4-4 DIP SW for encoder Z-phase method selection
CMP → STA DIP SW1-4
(3)
Enable
Disable
(4)
Counter clear (CLR)/Counter latch (LTC) selection
Both CLR and LTC are disabled OFF
Use CLR
Use LTC
This function provides three input options to select from for the deceleration sensor (DLS).
When using CLR or LTC, disable DLS by the software.
Table 3.4-6 DIP SW for Counter clear/ Counter latch selection
Front face direction
DIP SW1

Figure 3.4-3 DIP switches for module setting

SW1
1
2
ON
ON
OFF
OFF
SW1
3
ON
OFF
SW1
4
ON
OFF
Table 3.4-5 DIP SW for CMP → STA switching
SW2
1
ON
OFF
49
DIP SW2
Default
setting
DIP SW2
2
Remarks
OFF
DLS input enabled
OFF
DLS disabled by the software.
ON