Configuration Clock Source

3.2.9. Active Serial Configuration Software Settings

You must set the parameters in the Device and Pin Options of the Intel Quartus Prime software when using the AS
configuration scheme.
To set the parameters for AS configuration scheme, complete the following steps:
1. On the Assignments menu, click Device.
2. In the Device and Pin Options select the Configuration category.
a. Select Active Serial x4 from the Configuration scheme drop down menu.
b. Select Auto or 1.8 V in the Configuration device I/O voltage drop-down list.
Send Feedback
Configuration
Configuration
scheme
I/O voltage
Active serial
clock source
Frequency (MHz)
AS_CLK
71.5
80
100
108
125
133