Reference Board Summary
Table 13.
Configuration Jumper Settings on Carrier Board (Sheet 1 of 3)
Label
Jumper Name
PWROK signal to IOH and SIO select
J1
PWOK select
1-2 short: Internal signal by D33VS and SUS_S3#
2-3 short: external signal by ATX-POW
PSON# signal to ATX-POW control select
1-2 short: ATX-POW using by ATX-mode
J2
PSON select
2-3 short: ATX-POW using by AT-mode (This case main power
of ATX-POW is rised by ATX-POW switch on timing.)
+5V power rail (D50VA) source select
J3
5V power select
1-3, 2-4 short: using ATX-POW 5V
3-5, 4-6 short: using on board DC-DC converter 5V output
+3.3V power rail (D33VA) source select
3.3V power
J4
1-3, 2-4 short: using ATX-POW 3.3V
select
3-5, 4-6 short: using on board DC-DC converter 3.3V output
+1.2V power rail (D12VA) control signal select
1-2 short: using D33VA and it is enabled S5 state in IOH_PLA
IOH PLA Power
J5
3-4 short: using SUS_S5# and it is enabled S3 state in IOH PLA
select
5-6 short: using J6 select signal (this case is same state enable
in IOH_PLA and PLB)
+1.2V power rail (D12V) control signal select
IOH PLB Power
1-2 short: using SUS_S5# and it is enabled S3 state in
J6
select
IOH_PLB
3-4 short: using SUS_S3# and it is enabled S0 state in IOH PLB
PSON# signal Suspend signal select in ATX-POW node
PS_ON# to
J7
1-2 short: SUS_S5# select
ATXPOW select
2-3 short: SUS_S3# select
PSON# signal source select
ATXPOW UP
1-2 short: SIO output signal (SIO_PSON#) select
J9
Control Select
2-3 short: Suspend signal from COMe module select (in this
case, using suspend signal is depend on the J7 selection)
IOH_PLA Reset input select
1-2 short: reset assert by D33VA_D33V (IOPLA) Powerup
IOH PLA Reset
3-4 short: reset assert by SIO RSMRST#
J10
Select
5-6 short: reset assert by CB_RESET#
This jumper setting is linked with the IOH_PLA power selection
by J5.
IOH_PLB Reset input select
1-2 short: reset assert by SIO RSMRST#
IOH PLB Reset
3-4 short: reset assert by SIO KBDRST#
J11
Select
5-6 short: reset assert by CB_RESET#
This jumper setting is limited by the IOH_PLB power selection
by J6.
connection select between UART0 DTR port of IOH to RS232C
driver
UART0 port
J12
1-2 short: connect to RS232C driver
DTR connection
open: no connection (if the case of using UART0 port in baud
rate up 4Mbps, it is necessary to be set open.)
Note:
A jumper consists of two or more pins mounted on the board. When a jumper cap is placed over two pins, it is
designated as SHORT. When there are more than two pins on the jumper, the pins to be shorted are indicated as 1–2 (to
short pin 1 to pin 2), 2–3 (to short pin 2 to pin 3), etc. When no jumper cap is to be placed on the jumper, it is
designated as OPEN.
January 2012
Document Number: 324213-002
Setting Context
®
Intel
Atom™ Processor E660 with Intel
Initial Setting
(AC Adapter
Use Case)
1-2 short
2-3 short
3-5, 4-6 short
(for DC-DC
converter pow
validation)
3-5, 4-6 short
(for DC-DC
converter pow
validation)
1-2 short
(IOH_PLA is S5
state enabled)
1-2 short
(IOH_PLB is S3
state enabled)
2-3 short
2-3 short
1-2 short
(it is same as J5
setting)
3-4 short
1-2 short
®
Platform Controller Hub EG20T Development Kit
Initial Setting
(ATX-Power
Use Case)
1-2 short
1-2 short
3-5, 4-6 short
(for DC-DC
converter pow
validation)
3-5, 4-6 short
(for DC-DC
converter pow
validation)
1-2 short
(IOH_PLA is S5
state enabled)
1-2 short
(IOH_PLB is S3
state enabled)
2-3 short
2-3 short
1-2 short
(it is same as J5
setting)
3-4 short
1-2 short
User Manual