4. Remote System Update (RSU)
UG-20205 | 2019.10.09
Reconfiguration includes the following steps:
1. After the device exits power-on-reset (POR), the boot ROM loads flash memory from the first valid decision firmware from
one of the copies at addresses 0, 512k, 1024, or 1536 to initialize the SDM. The same configuration firmware is present in
each of these locations. This firmware is part of the initial RSU flash image. ( Refer to Step 2 of
Remote System Update Functions for Non-HPS
image into the flash.)
2. The optional Direct to Factory pin controls whether the SDM firmware loads the factory or application image. You can
assign the Direct to Factory input to any unused SDM pin. The SDM loads the application image if you do not assign this
pin.
3. The configuration pointer block in the flash device maintains a list of pointers to the application images.
4. When loading an application image, the SDM traverses the pointer block in reverse order. The SDM loads the highest
priority image. When image loading completes, the device enters user mode.
5. If loading the newest (highest priority) image is unsuccessful, the SDM tries the next application image from the list. If
none of the application loads successfully, the SDM loads the factory image.
6. If loading the factory image fails, you can recover by reprogramming the quad SPI flash with the initial RSU flash image
using the JTAG interface.

4.1.5. RSU Recovery from Corrupted Images

When an RSU fails, the Mailbox Client Intel FPGA IP
configuration status, including the currently running image and most recent failing image. The
the
RSU_STATUS
Configuration Support
Upgrade to expand this section, then click
Send Feedback
commands. You can download the
Center, click Advanced Configuration Features, click the triangle next to Remote System
Example of Tcl
on page 131 for step-by-step details for programming the initial RSU flash
command provides information about the current
RSU_STATUS
script from the following web page. Under
rsu1.tcl
Script.
Guidelines for Performing
script implements
rsu1.tcl
Device
Intel
®
Agilex
Configuration User Guide
127