4. Remote System Update (RSU)
UG-20205 | 2019.10.09
Command
Code
(Hex)
4
CONFIG_STATUS
(9)
This number does not include the command and response header.
Send Feedback
Command
Response
(9)
(9)
Length
Length
0
6
Reports the status of the last reconfiguration. You can use this command to check the
configuration status during and after configuration. The response contains the following
information:
Word
0
1
2
3
4
5
Description
Summary
Description
State
Describes the most recent configuration related error.
Returns 0 when there are no configuration errors.
The error field h
Upper 16 bits: Major error code.
Lower 16 bits: Minor error code.
Refer to the
Table 36
140 for more information.
Version
The version of the RSU data structure.
Pin status
Bit [31]: Current
Bit [30]: Detected
Bit [29:3]: Reserved
Bit [2:0]: The
Soft function status
Contains the value of each of the soft functions, even if
you have not assigned the function to an SDM pin.
Bit [31:6]: Reserved
Bit [5]:
HPS_WARMRESET
Bit [4]:
HPS_COLDRESET
Bit [3]:
SEU_ERROR
Bit [2]:
CVP_DONE
Bit [1]:
INIT_DONE
Bit [0]:
CONF_DONE
Error location
Contains the error location. Returns 0 if there are no
errors.
Error details
Contains the error details. Returns 0 if there are no
errors.
as 2 fields:
CONFIG_STATUS
on page 139 and
Table 37
on page
output value (active low)
nSTATUS
input value (active low)
nCONFIG
value at power up
MSEL
continued...