The PFL II IP core supports dual flash memory devices in burst read mode to achieve faster configuration times. You can
connect two MT29EW CFI flash memory devices to the host in parallel using the same data bus, clock, and control signals.
During FPGA configuration, the
Figure 20.
PFL II IP core with Dual CFI Flash Memory Devices
The flash memory devices must have the same memory density from the same device family and manufacturer.
CFI Compliant Flash
ADDR[24..0]
NCE
NWE
NOE
DATA[15..0]
CFI Compliant Flash
ADDR[24..0]
NCE
NWE
NOE
DATA[15..0]
3.1.10.1.2. Controlling Avalon-ST Configuration with PFL II IP Core
The PFL II IP core in the host determines when to start the configuration process, read the data from the flash memory
device, and configure the Intel Agilex device using the Avalon-ST configuration scheme.