Settings Conflict; Gate Is Not Available When Marker Count On - Keysight X-Series Manual

Signal analyzers, instrument messages
Hide thumbs Also See for X-Series:
Table of Contents

Advertisement

Instrument Messages
Event Messages
Err#
Message
-221
Settings conflict; Gate
is not available when
Marker Count on
-221
Settings conflict; Gate
Length is not settable in
FFT sweeps
-221
Settings conflict; Gate
Length is not settable in
FFT sweeps
-221
Settings conflict; Gate
Method is not compatible
with current Sweep Type
setting
-221
Settings conflict; Gate
not available with
external Tracking Source
-221
Settings conflict; Gate
not available with
Tracking Generator
-221
Settings conflict; Gated
FFT is not available while
Sweep Type is set to Swept
-221
Settings conflict; Gated
LO is not available while
Sweep Type is set to FFT
-221
Settings conflict; Gated
Video is not available
while Sweep Type is set to
FFT
-221
Settings conflict;
Incorrect RBW for demod.
Change RBW
-221
Settings conflict; Ind
I/Q is not available for
this measurement
-221
Settings conflict; Input
Port is not available
while occupied by Output
Instrument Messages
Verbose/Correction Information
The gate function cannot be used while you have marker count
turned on.
The sweep time for FFT sweeps is set by the calculations. So
sweep time settings cannot be adjusted.
The sweep time for FFT sweeps is set by the calculations. So
sweep time settings cannot be adjusted.
If the Gate is On and you have the FFT Sweep Type manually
selected, then the Gate Method cannot be selected.
The Gate functions are unavailable when Source Mode is Tracking
with an external source. This is because the Gate circuitry is used
to sync the external source.
If the Source Type is Tracking Generator, the Gate circuitry is
used for TG sync and is not available for gating
The gated FFT function is not available if you have selected the
swept type of sweep. You must be in the FFT sweep type.
The FFT sweep type moves the LO frequency in steps. So the
gated LO function is not available if you have selected FFT sweep.
The gated video function is not available if you have selected the
FFT sweep type.
The Independent I and Q setting is not available for the current
measurement. Only some measurements (initially, only VXA)
support this setting.
The desired destination for the Input Port is already occupied by
the Output Port. First set the Output to a different port or None.
Note the Output must be OFF before it can be changed to a
different port.