Data Out Of Range; Clipped To Source Max/Min - Keysight X-Series Manual

Signal analyzers, instrument messages
Hide thumbs Also See for X-Series:
Table of Contents

Advertisement

Instrument Messages
Event Messages
Err#
Message
-220
Parameter
error;Waveform
<filename> is already
assigned to a waveform
slot
-220
Parameter
error;Waveform cannot
be multi-pack
licensed, no
multi-pack slots
available
-220
Parameter
error;Waveform of that
ID is already
multi-pack licensed
-221
Settings conflict;
-222
Data out of range;
-222
Data out of Range;
clipped to source
max/min
-222
Data out of Range;
Dwell Time clipped to
minimum value allowed
-222
Data out of range;
Invalid Correction
Group range data
-222
Data out of range;
Invalid list data
-222
Data out of range;
Invalid slice data at
the number specified
-222
Data out of Range;
Scan Time limited,
multiple CISPR det's
in use for prescan
-222
Data out of Range;
Step Size clipped to
nearest value allowed
Instrument Messages
Verbose/Correction Information
An attempt was made to assign a waveform to a slot while the
waveform was already assigned to another waveform slot.
An attempt was made to multi-pack license a waveform, but there are
no free multi-pack license slots.
Install multi-pack licenses to get multi-pack license slots.
An attempt was made to multi-pack license a waveform that was
already licensed by a different multi-pack license slot.
There are many types of settings conflict errors. See section 3.5 for
information about these errors.
A data element was found but the instrument could not be set to that
value because it was outside the range defined for the command. A
descriptive message may be appended, such as "clipped to upper
limit"
A source parameter has been entered that exceeds the range of the
selected source. The parameter has been clipped to match the range
of the source
The dwell time entered could not be set to. It is clipped to the
minimum allowable value, which is determined by the smallest RBW
set in Scan Table.
You tried to set the data for a Correction Group range which is not
connecting to the range currently available.
You tried to use a trace that has a number of sweep points that is
different from the current setting of sweep points.
You tried to query for an invalid range of time slice data.
The scan time/ meas time entered could not be set to. Scan time is
limited to 2.4 ks with multiple CIPSR detectors turned on.
The step size entered could not be set to. It is clipped to the nearest
allowable value.
73