Instrument Messages
Event Messages
–300 to –399, Device-Specific Errors
Err#
Message
-300
Device-specific error
-310
System error;
-310
System error;
<feature> expired,
please reboot within
<time>
-310
System error;
<feature> expired,
rebooting in <time>
-310
System Error;
<filename> not
recalled
-310
System error; A
license will soon
expire;<feature code>
will expire in <time>
-310
System Error; enable
GPIB controller mode
-310
System error; feature
<feature code> not
licensed
-310
System error; Feature
expired; <feature
code>
-310
System error; License
installation
failed;<feature code>
-310
System error; License
removal failed;
<feature code>
-310
System error; No
license; <feature
code> will terminate
in <time>
Instrument Messages
Verbose/Correction Information
An instrument error occurred and the exact problem cannot be
specifically identified. Report this error to the nearest Keysight
Technologies sales or service office.
An internal system-type error has occurred. The exact problem cannot
be specifically identified. Report this error to the nearest Keysight
Technologies sales or service office.
The trial license for the specified feature, for example "N9030T-RT1, has
expired. You must finish any measurements in process and reboot the
instrument within the time specified.
The trial license for the specified feature, for example "N9030T-RT1, has
expired. The instrument will automatically reboot at the time specified;
you should save your measurement results immediately.
The auto recall of cal factor .xml file has failed. You should load the cal
factor manually from the recall dialog.
The indicated feature/software will expire in the specified time. Contact
Keysight Technologies to purchase continued use of this functionality.
Press System, I/O Config, GPIB and set GPIB Controller to Enabled so
that the analyzer can control the source over GPIB
The specified feature, for example "N9073A-TR2" is not licensed. The
license may have expired. You cannot use it until you get a license.
The specified feature has expired. The license is no longer valid.
The license installation of the specified feature, for example
"N9073A-TR2", has failed. You should refer to the event log in the
control panel for more details.
The license removal of the specified feature, for example "N9073A-TR2"
has failed. You should refer to the event log in the control panel for more
details.
The specified feature will stop working in the specified time due to the
license expiration You will be prompted to save results and exit.