Instrument Messages
Event Messages
Err#
Message
-221
Settings conflict; Radio
Band *** *** not available
in Radio Standard ***,
Acq=#
-221
Settings conflict; Radio
Device BTS not supported,
Acq=#
-221
Settings conflict; Radio
Standard *** not
available, Acq=#
-221
Settings conflict;
Reference marker must be
in same window
-221
Settings conflict;
Relative Trigger needs
hardware support for this
meas
-221
Settings conflict; RF
Envelope trace is not
available without Basic
IQ data measurement,
Acq=# Step=#
-221
Settings conflict; Sample
Rate is fixed
-221
Settings conflict; Scale
Type = Lin is not
available when Normalize
is on
-221
Settings conflict;
Sequence may have gaps
when playing step <n>, if
next step trigger comes
later than current step
expires
-221
Settings conflict;
Sequence too long, Acq = #
-221
Settings conflict;
Pre-trigger is
insufficient for demod.
Decrease Trig Delay.
Instrument Messages
Verbose/Correction Information
The radio band is not supported by the selected Radio Standard.
Change the radio band.
Sequence analyzer does not support BTS.
Change the device type of the acquisition radio standard related
mode to MS. For example: if acquisition 3 is configured as
WCDMA, so you should change the device type of WCDMA mode
to MS.
The radio standard related application is not preloaded.
Manually switch to the radio standard related mode and switch
back to Sequence Analyzer mode. Or select this mode as
preloaded in configure-application panel and then restart.
A delta marker and its reference must be in the same window.
This error occurs when you try to turn on a delta marker who's
reference is in a different window.
To do Relative Triggering in this measurement requires optional
hardware that is not present in this analyzer.
RF envelope view is available only when the selected analysis step
contains basic IQ data measurement.
Configure Basic IQ data measurement into current analysis step
or switch the view to Result Metrics.
You attempted to set the sample rate on a product with fixed
sample rate.
Only the Log amplitude scale is available in Normalize, since the
results are always presented as a dB ratio.
You set the step duration type of step n to Time or Play Count
while the Step Trigger of step n+1 is not set to "Free Run". So if
next step trigger comes later than the expiration of the current
step play time, the ARB will stop playing and cause a gap between
steps. This is a warning.
The duration of the whole sequence is too long. With current
configurations, The Sequence can only handle #-1 Acquisitions.