Instrument Messages
Event Messages
Err#
Message
-220
Parameter
error;License slot <n>
is locked, therefore
cannot be replaced
-220
Parameter
error;License slot <n>
is not assigned,
therefore cannot be
locked
-220
Parameter error;Nested
sequence file is not
supported
-220
Parameter error;Nested
sequence file is not
supported
-220
Parameter error;No.
<n> waveform file path
is invalid
-220
Parameter
error;Repetition value
must be within 1 and
65535
-220
Parameter
error;Sequence will be
stuck on step <step
number>. Next step
trigger cannot be free
run when current step
duration is continuous
-220
Parameter error;Suffix
of waveform sequence
file should be ".seq"
-220
Parameter
error;Transition time
is longer than
duration time on
step<step number>
-220
Parameter
error;Unrecognized
marker type: <marker>
Instrument Messages
Verbose/Correction Information
An attempt was made to replace a slot with another waveform while
the slot was already locked.
An attempt was made to lock a slot while the slot was not assigned.
An attempt was made to add a sequence file as a waveform segment
into another sequence file.
An attempt was made to build a new waveform sequence which
contains another waveform sequence file.
Do not nest waveform sequence file (*.seq) into another waveform
sequence file (*.seq).
An attempt was made to build a new waveform sequence while the nth
waveform file path is invalid or not specified.
Specify a correct path for the waveform.
An attempt was made to build a new waveform sequence with the
repetition value set to less than 1 or greater than 65535.
An attempt was made to set the current step duration to continuous,
while the step trigger of the next step is set to free run.
Make the next step trigger to be other than free run.
An attempt was made to build a new waveform sequence while the
suffix of waveform sequence file is not ".seq".
Ensure that the waveform sequence file suffix and file format is
consistent with "seq".
An attempt was made to set the source step transition time to a value
that is longer than step duration time, when the step duration type is
"Time".
Make the transition time shorter than the duration time.
An attempt was made to build a new waveform sequence while the
marker type value is invalid.
Input correct maker type parameter.