Settings Conflict; Marker Cannot Be Relative To Itself - Keysight X-Series Manual

Signal analyzers, instrument messages
Hide thumbs Also See for X-Series:
Table of Contents

Advertisement

Instrument Messages
Event Messages
Err#
Message
-221
Settings conflict; Marker
cannot be relative to
itself
-221
Settings conflict; Marker
Count is not available
when Gate on
-221
Settings conflict; Marker
Function is not available
for a Fixed marker
-221
Settings conflict; Marker
type must be delta
-221
Settings conflict;
Marker-> function is not
available in zero span
-221
Settings conflict; Mask
unavailable for current
Span. Increase to display
mask.
-221
Settings conflict; Meas
Type was changed to
Examine for Exp Avg Mode.
-221
Settings conflict; Meas
Type was changed to Full
for Repeat Avg Mode
-221
Settings conflict;
Measurement Bitmap ***
not available in Radio
Standard ***, Acq=#
-221
Settings conflict;
Minimum setting is only
available when Modulation
Mode is AM
-221
Settings conflict;
MinPts/RBW limit not met
-221
Settings conflict; Mkr ->
CF is not available when
the x-axis is time domain
-221
Settings conflict; Mod
Scheme AutoDet
unavailable when Burst
Sync=RF Amptd
Instrument Messages
Verbose/Correction Information
A marker must be set relative to another marker, not to itself.
The marker count function cannot be used while you have gating
turned on.
If a Marker is a Fixed type marker, the marker's value does not
change from when it first became fixed. You cannot turn on or
change a Marker Function because there is no ongoing
measurement data to use for the marker function calculation.
Mkr∆->Span and Mkr∆->CF require that the selected marker be
a delta marker.
Most of the "Marker To" functions are not available if you are in
zero span (span = 0 Hz, or time domain). So you cannot send the
commands for these functions.
The current span setting is either narrower than the mask width
or so wide that there are too few display points to allow the mask
to be drawn. Increase or decrease the span to display the mask.
Average Mode has been changed to Exponential. Full Meas Type
is not available for Exponential Average Mode therefore Meas
Type has been changed to Examine.
Average Mode has been changed to Repeat. Examine Meas Type
is not available for Repeat Average Mode therefore Meas Type has
been changed to Full.
The configured measurement is not supported by the current
radio standard.
Remove this measurement from the current acquisition or change
the radio standard of the current acquisition.
You are not allowed to change IF BW Type setting to Minimum if
you are not in AM Depth or Modulation Mode is not in AM.
The marker to center frequency functionality does not work when
the x-axis is in the time domain.
The modulation scheme auto detection is unavailable when the
burst sync is set to RF Amptd (GSM/EDGE)
58

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents