COPIER (Service mode for printer) > DISPLAY (State display mode) > DENS
DEV-DC-K
2
Detail
Use Case
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
CHG-DC-Y
2
Detail
Use Case
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
CHG-DC-M
2
Detail
Use Case
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
CHG-DC-C
2
Detail
Use Case
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
CHG-DC-K
2
Detail
Use Case
Display/Adj/Set Range
Unit
Appropriate Target Value
Amount of Change per
Unit
D-K-TRGT
2
Detail
Use Case
Display/Adj/Set Range
Appropriate Target Value
Dspl of Bk-color developing DC voltage
To display the latest Bk-color developing DC voltage Vdc.
- When image failure occurs due to carrier adherence
- When fogging occurs/is deteriorated
-1000 to 0
V
-490 - -600
1
Dspl Y-color primary charge DC voltage
To display the latest primary charging DC voltage of Y-color.
When decrease in density/fogging occurs
-1600 to 0
V
-1400 - -1200
1
Dspl M-color primary charge DC voltage
To display the latest primary charging DC voltage of M-color.
When decrease in density/fogging occurs
-1600 to 0
V
-1400 - -1200
1
Dspl C-color primary charge DC voltage
To display the latest primary charging DC voltage of C-color.
When decrease in density/fogging occurs
-1600 to 0
V
-1400 - -1200
1
Dspl Bk-color primary charge DC voltage
To display the latest primary charging DC voltage of Bk-color.
When decrease in density/fogging occurs
-1600 to 0
V
-1400 - -1200
1
Dspl Bk-clr patch target dens: ATR ctrl
To display the target density for Bk-color patch image formed at ATR control.
When analyzing the cause of image failure (fogging, carrier adherence, low density, etc.)
0 to 1023
150 - 500
573