Canon imageRUNNER ADVANCE C3500 III Series Service Manual page 736

Table of Contents

Advertisement

COPIER (Service mode for printer) > ADJUST (Adjustment mode) > EXP-LED
INTEXP-M
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
INTEXP-C
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
INTEXP-K
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Unit
Default Value
Amount of Change per
Unit
2
Adj Cln Pre-expo LED(M) initial intnsty
To adjust the initial light intensity of the Cleaning Pre-exposure LED (M).
When replacing the LED, enter the value written on the label included in the package of a new
one.
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
- When replacing the Cleaning Pre-exposure LED
- When replacing the DC Controller PCB/clearing RAM data
Enter the setting value, and then press OK key.
Use this item only when replacing the Cleaning Pre-exposure LED or replacing the DC Controller
PCB/clearing RAM data.
0 to 100
%
0
1
2
Adj Cln Pre-expo LED(C) initial intnsty
To adjust the initial light intensity of the Cleaning Pre-exposure LED (C).
When replacing the LED, enter the value written on the label included in the package of a new
one.
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
- When replacing the Cleaning Pre-exposure LED
- When replacing the DC Controller PCB/clearing RAM data
Enter the setting value, and then press OK key.
Use this item only when replacing the Cleaning Pre-exposure LED or replacing the DC Controller
PCB/clearing RAM data.
0 to 100
%
0
1
2
Adj Cln Pre-expo LED(Bk) initial intnsty
To adjust the initial light intensity of the Cleaning Pre-exposure LED (Bk).
When replacing the LED, enter the value written on the label included in the package of a new
one.
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
- When replacing the Cleaning Pre-exposure LED
- When replacing the DC Controller PCB/clearing RAM data
Enter the setting value, and then press OK key.
Use this item only when replacing the Cleaning Pre-exposure LED or replacing the DC Controller
PCB/clearing RAM data.
0 to 100
%
0
1
714