COPIER (Service mode for printer) > FUNCTION (Operation / inspection mode) > INSTALL
E-RDS
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Related Service Mode
Supplement/Memo
RGW-PORT
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Related Service Mode
Supplement/Memo
COM-TEST
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Related Service Mode
Supplement/Memo
COM-LOG
1
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Related Service Mode
Supplement/Memo
ON/OFF of Embedded-RDS
To set whether to use the E-RDS.
When using Embedded-RDS
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and RGW-ADR as a set.
0 to 1
0: Not used, 1: Used (All the counter information is sent.)
It differs according to the location.
COPIER> FUNCTION> INSTALL> RGW-PORT, COM-TEST, COM-LOG, RGW-ADR
COPIER> FUNCTION> CLEAR> ERDS-DAT
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to the sales company's server via SOAP protocol
Set port number of Sales Co's server
To set the port number of the sales company's server to be used for Embedded-RDS.
When using Embedded-RDS
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and RGW-ADR as a set.
1 to 65535
443
COPIER> FUNCTION> INSTALL> E-RDS, COM-TEST, COM-LOG, RGW-ADR
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to the sales company's server via SOAP protocol
Dspl connect result w/ Sales Co's server
To display the result of the connection test with the sales company's server.
When using Embedded-RDS
Select the item, and then press OK key.
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and RGW-ADR as a set.
During operation: ACTIVE, When connection is completed: OK, When connection is failed: NG
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-LOG, RGW-ADR
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to the sales company's server via SOAP protocol
Dspl connect error w/ Sales Co's server
To display error information when the connection with the sales company's server failed.
When using Embedded-RDS
N/A (Display only)
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and RGW-ADR as a set.
Year, date, time, error code, error detail information (maximum 128 characters)
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST, RGW-ADR
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to the sales company's server via SOAP protocol
718
8. Service Mode