10. Put the Reader Flat Cable along the guide in the figure and attach it to the Reader Scanner Unit with the double
sided tape [1]. The distance of differences between [A] and [B] must be under 1.0mm.
CAUTION:
• When the distance of differences between [A] and [B] is over 1.0mm, adjust the distance under 1.0mm while removing
the double sided tape.
• When fixing the Reader Flat Cable with the distance of differences between [A] and [B] is over 1.0mm, it may occur
disconnection of the Reader Flat Cable.
11. Attach the protection sheet [1].
• 2 Guides [2]
• 2 Claws [3]
[B]
2x
[1]
[3]
4. Parts Replacement and Cleaning
[A]
[2]
184
[1]