E064-1103-05
Detection Description
Remedy
E064-1201-05
Detection Description
Remedy
High voltage error
[Related parts]
- Secondary Transfer High-Voltage PCB
- DC Controller PCB
- Harness between the DC Controller PCB and the Secondary Transfer High-Voltage PCB
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check the Harness (on the DC Controller side and the Secondary Transfer High-Voltage PCB
side).
If it is not fully connected or obliquely connected, check the operation of the main machine by
disconnecting it then connecting it again.
2. If no error is seen in the Harness in Procedure 1 or if an error is not cleared by disconnecting it
and then connecting it again, replace the Secondary Transfer High-Voltage PCB and check the
operation of the main machine.
3. If an error is not cleared in Procedure 2, replace the DC Controller PCB and check the operation
of the main machine.
[Reference]
Before replacing the DC Controller PCB, back up the service mode data and restore the backup
data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
High voltage error
[Related parts]
- Secondary Transfer High-Voltage PCB
- DC Controller PCB
- Harness between the DC Controller PCB and the Secondary Transfer High-Voltage PCB
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check the Harness (on the DC Controller side and the Secondary Transfer High-Voltage PCB
side).
If it is not fully connected or obliquely connected, check the operation of the main machine by
disconnecting it then connecting it again.
2. If no error is seen in the Harness in Procedure 1 or if an error is not cleared by disconnecting it
and then connecting it again, replace the Secondary Transfer High-Voltage PCB and check the
operation of the main machine.
3. If an error is not cleared in Procedure 2, replace the DC Controller PCB and check the operation
of the main machine.
[Reference]
Before replacing the DC Controller PCB, back up the service mode data and restore the backup
data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES