E355-0004-00 System Error; E400-0001-04 Communication Error; E400-0002-04 Communication Error; E400-0003-04 Communication Error - Canon imageRUNNER ADVANCE C3500 III Series Service Manual

Table of Contents

Advertisement

E355-0004-00
Detection Description
Remedy
E400-0001-04
Detection Description
Remedy
E400-0002-04
Detection Description
Remedy
E400-0003-04
Detection Description
Remedy
E412-0005-04
Detection Description
Remedy
E412-0006-04
Detection Description
Remedy
System error
System error
Contact to the sales company.
Communication error
A communication error between the Main Controller PCB and the DADF Driver PCB was detected.
[Related parts]
- Harness between the Main Controller PCB (UN05) and the ADF Driver PCB
- ADF Driver PCB
- Main Controller PCB (UN05)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the Main Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Communication error
A communication error between the Main Controller PCB and the DADF Driver PCB was detected.
[Related parts]
- Harness between the Main Controller PCB (UN05) and the ADF Driver PCB
- ADF Driver PCB
- Main Controller PCB (UN05)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the Main Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Communication error
Disconnection of the harness between the Main Controller PCB and the DADF Driver PCB was
detected.
[Related parts]
- Harness between the Main Controller PCB (UN05) and the ADF Driver PCB
- ADF Driver PCB
- Main Controller PCB (UN05)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the Main Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Fan error
Rotation of fan was detected after the stop signal for the DADF Cooling Fan was transmitted.
[Related parts]
- DADF Cooling Fan (FAN_A1)
- DADF Driver PCB (PCB1)
[Remedy] Check/replace the related parts.
Fan error
Stop of fan was detected after rotation signal for the DADF Cooling Fan was transmitted.
[Related parts]
- DADF Cooling Fan (FAN_A1)
- DADF Driver PCB (PCB1)
[Remedy] Check/replace the related parts.
386
7. Error/Jam/Alarm

Advertisement

Table of Contents
loading