Appendices; Appendix 1 Special Relays/Special Registers; Appendix 1.1 Special Relays - Mitsubishi Electric Q Series Programming Manual

Common. motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

APPENDICES

APPENDICES

APPENDIX 1 Special Relays/Special Registers

APPENDIX 1.1 Special relays

Special relays are internal relays whose applications are fixed in the Motion CPU. For
this reason, they cannot be used in the same way as the normal internal relays by the
Motion SFC programs (SV13/SV22)/Motion programs (SV43).
However, they can be turned ON/OFF as needed in order to control the Motion CPU.
The headings in the table that follows have the following meanings.
No.
Name
Meaning
Details
Set by
(When set)
Item
• Indicates the device No. of the special relay.
• Indicates the name of the special relay.
• Indicates the nature of the special relay.
• Indicates detailed information about the nature of the special relay.
• Indicates whether the relay is set by the system or user, and, if it is set by system, when
setting is performed.
<Set by>
S: Set by system (Motion CPU)
U: Set by user (Motion SFC program/Motion program or test operation using
MT Developer2)
S/U: Set by both system (Motion CPU) and user
<When set>
Indicated only if setting is done by system (Motion CPU).
Main process: Set during each main processing (free time processing of the CPU)
Initial process: Set only during initial processing (when power supply is turned ON, or
when executed the reset)
Status change : Set only when there is a change in status
Error : Set when error is occurred.
Request : Set only when there is a user request (Special relay, etc.)
Operation cycle : Set during each operation cycle of the Motion CPU.
APP - 1
Explanation
APP.

Advertisement

Table of Contents
loading

Table of Contents