4 AUXILIARY AND APPLIED FUNCTIONS

4.4.3 Operating procedure of the ROM operation function

(1) ROM operation procedure
The ROM operation procedure is shown below.
Set the "Mode operated by RAM" by setting
the rotary switch 1 (SW1) and 2 (SW2) to "0".
Turn ON the power supply of Multiple CPU
system.
Create or correct the system setting,
parameters and programs using the
MT Developer2, and write them to the
Motion CPU module.
Execute the trial run and adjustment.
Mode operated
Write the system setting, parameters, and
by RAM
programs of SRAM built-in Motion CPU
(ROM writing)
module to the FLASH ROM built-in Motion
CPU module by the ROM writing request
using the MT Developer2.
Turn OFF the power supply of Multiple CPU
system.
Set the "Mode operated by ROM" by setting
the rotary switch 1 (SW1) to "0" and rotary
switch 2 (SW2) to "6".
Turn ON the power supply of Multiple CPU
system.
Mode operated
by ROM
Preparation for ROM operation
Is the operation normal ?
YES
ROM operation start
4 - 29