Mitsubishi Electric Q Series Programming Manual page 118

Common. motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

4 AUXILIARY AND APPLIED FUNCTIONS
1) Without output enable/disable bit/forced output settings
2) With output enable/disable bit/forced output settings
(3) Forced output bit can be set and turned the forcibly output of the limit switch
outputs point-by-point ON.
The output is ON when the forced output bit is ON. Priority is given to control of
this setting over off (disable) of the "output enable/disable bit".
If there is no setting, no forced outputs are not always made.
(4) When the multiple watch data, ON region, output enable/disable bit and forced
output bit are set to the same output device, the logical add of output results of the
settings is output.
SM500
Output device
OFF Value
ON section setting
ON Value
Watch data value
Output device
Enable/disable bit
Forced output bit
ON
Output control based on
Output OFF
ON Value and OFF Value
Output control based on
Output OFF
ON Value and OFF Value
4 - 3
Output ON
(Forced output)
Output OFF
Output OFF
Output ON
(Forced output)

Advertisement

Table of Contents
loading

Table of Contents