Mitsubishi Electric Q Series Programming Manual page 225

Common. motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

4 AUXILIARY AND APPLIED FUNCTIONS
(g) Command device
Set the device for commands to SSCNET /H head module.
1) Usable devices are shown below.
• Bit device
Bit device
M
B
(Note-1): Set the start device as a unit of 16 points.
• Word device
Word device
D
W
#
U \G
(Note-1): "p" indicates the user setting area points of the Multiple CPU high
speed transmission area for each CPU.
2) The device uses 16 points (1 point if a word device) from the specified
device number.
The details stored in the command device are shown below.
Off set
+0
+1
+2
+3
+4
+5
+6
+7
+8
+9
+10
+11
+12
+13
+14
+15
4 - 110
Setting range
Setting range
10000 to (10000+p-1)
Signal name
Unusable
Error reset command
Unusable
(Note-1)
0 to 8191
0 to 1FFF
0 to 8191
0 to 1FFF
0 to 9215
(Note-1)
Refresh cycle
Main cycle