4 AUXILIARY AND APPLIED FUNCTIONS
(c) High-speed input request signal valid flag
The high-speed input request signal is valid only when the flag is ON.
The high-speed input request signal is invalid when the flag is OFF.
This setting can be omitted.
The high-speed input request signal is always valid when it is ignored.
Bit device
X
Y
M
B
10000.0 to (10000+p-1).F
U \G
(Note-1): The range of "PXn+4 to PXn+F" cannot be used (fixed at 0) for the input device (PXn+0 to
PXn+F) allocated to the built-in interface in Motion CPU (DI). (n: First input No.)
(Note-2): "p" indicates the user setting area points of the Multiple CPU high speed transmission area
for each CPU.
(d) High-speed input request signal status
The ON/OFF status of high-speed input request signal can be monitored.
ON/OFF status can be monitored regardless of the status of the high-speed
input request signal valid flag.
This setting can be omitted.
Bit device
X
Y
M
B
10000.0 to (10000+p-1).F
U \G
(Note-1): The range of "PXn+4 to PXn+F" cannot be used (fixed at 0) for the input device (PXn+0 to
PXn+F) allocated to the built-in interface in Motion CPU (DI). (n: First input No.)
(Note-2): "p" indicates the user setting area points of the Multiple CPU high speed transmission area
for each CPU.
POINT
When signal is inputted in a state where the detection of high-speed input request
signal is unnecessary ([St.380] Synchronous control (M10880+n) is turned OFF, or
[Rq.320] Synchronous encoder axis control request (M11601+4n) is turned OFF),
the high-speed input request signal valid flag turns OFF. Turn ON when the
detection of high-speed input request signal is necessary.
Setting range
(Note-1)
0 to 1FFF
0 to 1FFF
0 to 8191
0 to 1FFF
(Note-2)
Setting range
(Note-1)
0 to 1FFF
0 to 1FFF
0 to 8191
0 to 1FFF
(Note-2)
4 - 93
Remarks
ON/OFF command is input when the
high-speed input request signal is
detected.
Remarks
The ON/OFF status is reflected for
every operation cycle.