Mitsubishi Electric Q Series Programming Manual page 241

Common. motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

APPENDICES
No.
Name
SD722
222µs coasting
222µs coasting
SD723
timer
QDS
timer
• Connect/
disconnect of
SSCNET
SSCNET control
SD803
communication
(Command)
• Start/release of
amplifier-less
operation
Servo parameter
SD804
write/read request
(Note-1)
flag
SD805
Axis No.
Servo parameter
write/read
request
QDS
Servo parameter
SD806
No.
Servo parameter
SD807
value
Servo parameter
SD808
setting value
SD809
(2 word)
Table 1.2 Special register list (Continued)
Meaning
• Current value (SD722, SD723) is incremented by 1 per 222µs.
Read SD722 device in 2 word unit.
• This register is not updated when the operation cycle is set to other than
0.2ms.
Item
Data size
Latch
Usable tasks
Access
Timer specifications
• SD803 is required for connect/disconnect of SSCNET communication and
start/release of amplifier-less operation.
0 : No command
1 to 32 : Disconnect command of SSCNET communication
-10 : Connect command of SSCNET communication
-20 : Start command 1 of amplifier-less operation (EMI invalid)
-21 : Start command 2 of amplifier-less operation (EMI valid)
-25 : Release command of amplifier-less operation
-2 : Execute command
• The "write/read request" is executed after setting of the axis No. and servo
parameter No.
1: Write request
2: Read request
3: 2 word write request
4: 2 word read request
• "0" is automatically set by Motion CPU after completion of servo parameter
write/read request. ("-1" is stored by Motion CPU at write/read error.)
• The axis No. to write/read servo parameter is stored.
Q173DSCPU: 1 to 32
Q172DSCPU: 1 to 16
• The servo parameter No. to be written/read is stored in hexadecimal.
H
• VC series use
H
• The setting value of servo parameter to be written is stored when "1: Write
request" is set in SD804.
• The setting value of servo parameter to be written is stored when "3: 2 word
write request" is set in SD804.
Details
Specification
2 word (-2147483648 to 2147483647)
Cleared to zero at power-on or reset, a count
rise is continued from now on.
Normal, event, NMI
Read only enabled
222µs timer
(Note-2)
(Note-2)
Parameter No.
Parameter group No.
0: PA
5: PF
1: PB
9: Po
2: PC
A: PS
3: PD
B: PL (MR-J4(W)- B only)
4: PE
C: PT (MR-J4(W)- B only)
Fixed at 0
Parameter No.
Parameter group No.
0: Group 0
5: Group 5
1: Group 1
6: Group 6
2: Group 2
7: Group 7
3: Group 3
8: Group 8
4: Group 4
9: Group 9
APP - 12
Set by
(When set)
S (222µs)
U
S/U
U
(Note-1): Do not execute the automatic refresh.
(Note-2): This can be set only in VC series.
Remark