Mitsubishi Electric Q Series Programming Manual page 202

Common. motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

4 AUXILIARY AND APPLIED FUNCTIONS
b) Estimate calculation : Invalid
Calculation for word device data in operation cycle is not estimated.
The latch data is the word device data at the timing in which the
mark detection signal is input. The detection accuracy is the
operation cycle regardless of the mark detection signal type.
Latch data
Mark detection signal
(e) Mark detection data storage device
Set the mark detection data storage device (first device to use in the
"Specified Number of Detections mode" or "Ring Buffer mode").
When using the "Specified Number of Detections mode" or "Ring Buffer
mode", reserve the device area to accommodate the number of detections.
Setting range
Word device
D
W
#
U \G
10000 to (10000+p-1)
(Note-1): Set an even numbered device in the 32-bit integer type/64-bit floating-point type.
(Note-2): The range of D0 to D19823 is valid in the SV22 advanced synchronous control.
(Note-3): The data can be stored in #9216 to #12287 in the "Specified Number of Detections mode"
or "Ring Buffer mode".
(Note-4): "p" indicates the user setting area points of the Multiple CPU high speed transmission area
for each CPU.
(Note-1)
(Note-2)
0 to 8191
0 to 1FFF
(Note-3)
0 to 9215
(Note-4)
4 - 87
Operation
cycle
Remarks
Word device data
t

Advertisement

Table of Contents
loading

Table of Contents