4 AUXILIARY AND APPLIED FUNCTIONS
(6) Forced OFF bit
(a) Set the "forced OFF bit" when forced OFF of the output device is desired
during operation.
The following control is exercised.
Forced OFF bit
Without setting
With setting
(b) Usable devices
Item
(Note-1)
Input relay
Output relay
Internal relay
Link relay
Annunciator
Special relay
Multiple CPU area device
(Note-1): The real input range(PX) is included.
(Note-2): The range of "PXn+4 to PXn+F" cannot be used (fixed at 0) for the input
device (PXn+0 to PXn+F) allocated to the built-in interface in Motion CPU
(DI). (n: First input No.)
(Note-3): The real input range(PY) is included.
(Note-4): "p" indicates the user setting area points of the Multiple CPU high speed
transmission area for each CPU.
Output device is turned ON/OFF based on the ON
section setting.
OFF
ON
Output device is turned OFF.
(Note-3)
U \G10000.0 to U \G (10000+p-1).F
4 - 15
Control description
Device No. setting range
(Note-2)
X0 to X1FFF
Y0 to Y1FFF
M0 to M12287
B0 to B1FFF
F0 to F2047
SM0 to SM1999
(Note-4)