Appendix 1
The buffer memory is used to exchange data between the Motion module and the CPU module. Buffer memory values are
reset to default when the CPU module is reset or the system is powered off.

List of buffer memory addresses

: Same as the address of P1
P1
Address (decimal)
Address
(hexadecimal)
0 to 57343
0 to DFFFH
57344 to 58367
E000H to E3FFH
58368 to 59391
E400H to E7FFh
59392 to 67583
E800H to 107FFH
67584 to 75775
10800H to 127FFH
75776 to 92159
12800H to 167FFH
92160 to 94207
16800H to 16FFFH
94208 to 94463
17000H to 170FFH
94464 to 98559
17100H to 180FFH
98560 to 1245439
18100 to 1300FFH
1245440 to 1245441
130100H to 130101H
1245442
130102H
1245443
130103H
1245444 to 1245445
130104H to 130105H
1245446
130106H
1245447 to 1245455
130107H to 13010FH
1245456 to 1245567
130110H to 13017FH
1245568 to 1245695
130180H to 1301FFH
1245696 to 1245697
130200H to 130201H
1245698 to 1245699
130202H to 130203H
1246176 to 1246177
1303E0H to 1303E1H
1246178 to 1246179
1303E2H to 1303E3H
1246180 to 1246719
1303E4H to 1305FFH
Buffer Memory (When Using the
PLCopen Motion Control FB Mode)
P2
Address
Address
(decimal)
(hexadecimal)

Appendix 1 Buffer Memory (When Using the PLCopen Motion Control FB Mode)

Name
System area
Link device area
Remote input
(RX)
Remote output
(RY)
Remote register
(RWw)
Remote register
(RWr)
Link register(LW)
Link relay(LB)
Link special
relay (SB)
Link special
register (SW)
System area
Timeslot 0
Cycle start offset
information
(ns unit)
Cycle start offset
(s unit)
System area
Cycle end offset
(ns unit)
Cycle end offset
(s unit)
System area
Timeslot 1 to 7
Same as
information
Timeslot 0
information
System area
RX offset/size
Station No. 0 RX
*1
information
offset
Station No. 0 RX
size
Station No. 120
RX offset
Station No. 120
RX size
System area
Initial
Read,
value
write
0
Read
Read,
write
Read
0
Read,
write
0
Read,
write
A
0
Read
0
Read
0
Read
0
Read
0
Read
0
Read
0
Read
APPX