4 AUXILIARY AND APPLIED FUNCTIONS
(b) As the output device, the following devices can be used.
Item
(Note-1)
Input relay
(Note-2)
Output relay
(Note-3)
Internal relay
Link relay
Multiple CPU area device
(Note-1): PX is write-disabled and it cannot be used as the output device.
For X, only the free No. of the input card non-loading can be used.
(Note-2): The real output device range (PY) is also included.
(Note-3): Be careful because it affect a positioning operation, when the positioning
dedicated devices are set.
(Note-4): The range of "PXn+4 to PXn+F" cannot be used (fixed at 0) for the input
device (PXn+0 to PXn+F) allocated to the built-in interface in Motion CPU
(DI). (n: First input No.)
(Note-5): "p" indicates the user setting area points of the Multiple CPU high speed
transmission area for each CPU.
(Note-6): Only device of the self CPU can be used.
(c) When the 16 point unit batch output setting is valid, the batch output of the
sequential 16 point unit devices has less effect on the operation cycle as
compared with the output of each output device point-by-point.
When the 16 point unit batch output setting is valid, it is recommended to set
multiple output devices as sequential 16 point unit output devices.
The sequential devices to be output in a 16 point unit batch is counted as
one set and up to 4 sets can be set.
When the 16 point unit batch output setting is valid, among the 16 point unit
devices, the devices that are not used as the output devices are always OFF.
16 point unit batch
output setting
Invalid
Valid
Device No. setting range
U \G10000.0 to U \G (10000+p-1).F
QDS
Control description
The output device is output point-by-point.
The sequential 16-point output devices are output in a batch.
4 - 11
(Note-4)
X0 to X1FFF
Y0 to Y1FFF
M0 to M8191
B0 to B1FFF
(Note-5), (Note-6)