4 AUXILIARY AND APPLIED FUNCTIONS
(7) Forced ON bit
(a) Set the "forced ON bit" when forced ON of the output device is desired
during operation.
The following control is exercised.
Forced ON bit
Without setting
With setting
(b) Usable devices
Item
Input relay
Output relay
Internal relay
Link relay
Annunciator
Special relay
Multiple CPU area device
(Note-1): The range of "PXn+4 to PXn+F" cannot be used (fixed at 0) for the input
device (PXn+0 to PXn+F) allocated to the built-in interface in Motion CPU
(DI). (n: First input No.)
(Note-2): "p" indicates the user setting area points of the Multiple CPU high speed
transmission area for each CPU.
POINT
Refer to Chapter 2 for the user setting area points of the Multiple CPU high speed
transmission area.
Output device is turned ON/OFF based on the ON
section setting .
OFF
ON
Output device is turned ON.
U \G10000.0 to U \G (10000+p-1).F
4 - 16
Control description
Device No. setting range
(Note-1)
X0 to X1FFF
Y0 to Y1FFF
M0 to M8191
B0 to B1FFF
F0 to F2047
SM0 to SM1999
(Note-2)