Mitsubishi Electric Q Series Programming Manual page 121

Common. motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

4 AUXILIARY AND APPLIED FUNCTIONS
2) Word device data
Item
Data register
Link register
Motion register
Multiple CPU area device
(Note-1): "p" indicates the user setting area points of the Multiple CPU high speed
transmission area for each CPU.
3) The following data type is set as the data type to be compared.
Data type
16-bit integer type
32-bit integer type
64-bit floating-point type
(3) ON section setting
(a) The data range which makes the output device turn ON/OFF toward the
watch data.
(b) The following devices can be used as the ON Value and OFF Value of the
data range.
The data type of device/constant to be set is the same as the type of watch
data.
Item
Data register
Link register
Motion register
Multiple CPU area device
Constant
(Note-1) : "p" indicates the user setting area points of the Multiple CPU high speed
transmission area for each CPU.
(4) Output enable/disable bit
(a) Set the status of output enable/disable bit when the limit switch output is
forbidden during operation.
The following control is exercised.
Output enable/disable bit
Without setting
(always enable)
With setting
U \G10000 to U \G (10000+p-1)
U \G10000 to U \G (10000+p-1)
Limit switch output is turned ON/OFF based on the
ON section setting (ON Value, OFF Value).
ON (enable)
OFF (disable) Limit switch output is turned OFF.
4 - 6
Device No. setting range
D0 to D8191
W0 to W1FFF
#0 to #9215
Remarks
Set the device No. as an even No.
Device No. setting range
D0 to D8191
W0 to W1FFF
#0 to #9215
Hn/Kn
Control description
(Note-1)
(Note-1)