Setting The Drive Control Parameters - ABB ACSM1 Firmware Manual

Motion control drives, speed and torque control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

346

Setting the drive control parameters

The Setting for fieldbus control column gives the value to use when the fieldbus
interface is the desired source or destination for that particular signal. The Function/
Information column gives a description of the parameter.
Parameter
10.01 EXT1 START
FUNC
10.04 EXT2 START
FUNC
24.01 SPEED REF1 SEL
24.02 SPEED REF2 SEL
32.01 TORQ REF1 SEL
32.02 TORQ REF ADD
SEL
16.07 PARAM SAVE
Appendix A – Fieldbus control
Setting for
fieldbus control
CONTROL COMMAND SOURCE SELECTION
(3) FBA
Selects fieldbus as the source for the start and stop commands when
EXT1 is selected as the active control location.
(3) FBA
Selects fieldbus as the source for the start and stop commands when
EXT2 is selected as the active control location.
(3) FBA REF1
Fieldbus reference REF1 or REF2 is used as speed reference 1.
(4) FBA REF2
(3) FBA REF1
Fieldbus reference REF1 or REF2 is used as speed reference 2.
(4) FBA REF2
(3) FBA REF1
Fieldbus reference REF1 or REF2 is used as torque reference 1.
(4) FBA REF2
(3) FBA REF1
Fieldbus reference REF1 or REF2 is used for torque reference
(4) FBA REF2
addition.
SYSTEM CONTROL INPUTS
(0) Done
Saves parameter value changes (including those made through
(1) Save
fieldbus control) to permanent memory.
Function/Information