Switchc - ABB ACSM1 Firmware Manual

Motion control drives, speed and torque control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

SWITCHC

(10064)
Illustration
Execution time
Operation
Inputs
Outputs
1.53 µs (when two inputs are used) + 0.73 µs (for every additional input). When all
inputs are used, the execution time is 23.31 µs.
The output (OUT) is equal to the corresponding channel A input (CH A1...32) if the
activate input (ACT) is 0. The output is equal to the corresponding channel B input (CH
B1...32) if the activate input (ACT) is 1.
The input data type and the number of inputs (1...32) are selected by the user.
Activate input (ACT): Boolean
Input (CH A1...CH A32, CH B1...CH B32): INT, DINT, REAL, REAL24, Boolean
Output (OUT1...OUT32): INT, DINT, REAL, REAL24, Boolean
327
Standard function blocks

Advertisement

Table of Contents
loading

Table of Contents