Parwr - ABB ACSM1 Firmware Manual

Motion control drives, speed and torque control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

Operation
Inputs
Outputs

PARWR

(10080)
Illustration
Execution time
Operation
Inputs
Outputs
Reads the internal (non-scaled) value of the source of a pointer parameter. The pointer
parameter is specified using the Group and Index inputs.
The value of the source selected by the pointer parameter is provided by the Output pin.
Error codes are indicated by the error output (Error) as follows:
Error code
Description
0
No error or busy
<> 0
Error
Parameter group (Group): DINT
Parameter index (Index): DINT
Output (Output): Boolean, INT, DINT, REAL, REAL24
Error output (Error): DINT
14.50 µs
The input value (IN) is written to the defined parameter (Group and Index).
The new parameter value is stored to the flash memory if the store input (Store) is 1.
Note: Cyclic parameter value storing can damage the memory unit. Parameter values
should be stored only when necessary.
Error codes are indicated by the error output (Error) as follows:
Error code
Description
0
No error
<> 0
Error
Input (IN): DINT
Parameter group input (Group): DINT
Parameter index input (Index): DINT
Store input (Store): Boolean
Error output (Error): DINT
319
Standard function blocks