MOVE

(10005)
Illustration
Execution time
Operation
Inputs
Outputs
MUL
(10006)
Illustration
Execution time
Operation
Inputs
Outputs
MULDIV
(10007)
Illustration
Execution time
2.10 µs (when two inputs are used) + 0.42 µs (for every additional input). When all
inputs are used, the execution time is 14.55 µs.
Copies the input values (IN1...32) to the corresponding outputs (OUT1...32).
The input data type and number of inputs (2...32) are selected by the user.
Input (IN1...IN32): INT, DINT, REAL, REAL24, Boolean
Output (OUT1...OUT32): INT, DINT, REAL, REAL24, Boolean
3.47 µs (when two inputs are used) + 2.28 µs (for every additional input). When all
inputs are used, the execution time is 71.73 µs.
The output (OUT) is the product of the inputs (IN).
O = IN1 × IN2 × ... × IN32
The output value is limited to the maximum and minimum values defined by the selected
data type range.
The input data type and the number of inputs (2...32) are selected by the user.
Input (IN1...IN32): INT, DINT, REAL, REAL24
Output (OUT): INT, DINT, REAL, REAL24
7.10 µs