ABB ACSM1 Firmware Manual page 202

Motion control drives, speed and torque control program
Hide thumbs Also See for ACSM1:
Table of Contents

Advertisement

202
97.07 LQ USER
Defines the quadrature axis (synchronous) inductance.
Note: This parameter is valid only for permanent magnet motors.
0...10 p.u. (per unit)
97.08 PM FLUX USER
Defines the permanent magnet flux.
Note: This parameter is valid only for permanent magnet motors.
0...2 p.u. (per unit)
97.09 RS USER SI
Defines the stator resistance R
0.00000...100.00000 ohm
97.10 RR USER SI
Defines the rotor resistance R
Note: This parameter is valid only for asynchronous motors.
0.00000...100.00000 ohm
97.11 LM USER SI
Defines the main inductance L
Note: This parameter is valid only for asynchronous motors.
0.00...100000.00 mH
97.12 SIGL USER SI
Defines the leakage inductance
Note: This parameter is valid only for asynchronous motors.
0.00...100000.00 mH
97.13 LD USER SI
Defines the direct axis (synchronous) inductance.
Note: This parameter is valid only for permanent magnet motors.
0.00...100000.00 mH
97.14 LQ USER SI
Defines the quadrature axis (synchronous) inductance.
Note: This parameter is valid only for permanent magnet motors.
0.00...100000.00 mH
Parameters and firmware blocks
FW block: None
Quadrature axis (synchronous) inductance.
FW block: None
Permanent magnet flux.
FW block: None
of the motor model.
S
Stator resistance.
FW block: None
of the motor model.
R
Rotor resistance.
FW block: None
of the motor model.
M
Main inductance.
FW block: None
σ
L
.
S
Leakage inductance.
FW block: None
Direct axis (synchronous) inductance.
FW block: None
Quadrature axis (synchronous) inductance.

Advertisement