Basics of the fieldbus adapter interface

The cyclic communication between a fieldbus system and the drive consists of 16/
32-bit input and output data words. The drive supports at the maximum the use of 12
data words (16 bits) in each direction.
Data transmitted from the drive to the fieldbus controller is defined by parameters
52.01 FBA DATA IN1...52.12 FBA DATA IN12
controller to the drive is defined by parameters
DATA
Fieldbus network
Fieldbus adapter module
DATA
2)
OUT
4)
1
2
3
...
12
Fieldbus-
specific
DATA
interface
2)
IN
5)
1
2
3
...
12
Cyclic communication
Acyclic communication
See the manual of the fieldbus
adapter module.
1) See also other parameters which can be controlled by the fieldbus.
2) The maximum number of used data words is protocol-dependent.
3) Profile/instance selection parameters. Fieldbus module specific parameters. For more information, see the
User's Manual of the appropriate fieldbus adapter module.
4) With DeviceNet, the control part is transmitted directly.
5) With DeviceNet, the actual value part is transmitted directly.
Control Word and Status Word
The Control Word (CW) is the principal means of controlling the drive from a fieldbus
system. The Control Word is sent by the fieldbus controller to the drive. The drive
OUT12.
Profile
selection
DATA OUT
selection
3)
Profile
Group 53
select ion
DATA IN
selection
3)
Group 52
and data transmitted from the fieldbus
53.01 FBA DATA OUT1...53.12 FBA
FBA profile
2.12 FBA MAIN CW
4)
2.14 FBA MAIN REF1
2.15 FBA MAIN REF2
Par. 10.01...99.13
2.13 FBA MAIN SW
5)
FBA ACT1
FBA ACT2
Par. 01.01...99.13
1)
EXT1/2
Start func
10.01/10.04
REF1 Sel
24.01/32.01/
32.02
REF2 Sel
24.02/32.01/
32.02
Parameter
table
Appendix A – Fieldbus control
347