SWITCH

(10063)
Illustration
Execution time
Operation
Inputs
Outputs
Standard function blocks
The input (I) value is stored to the output (OA1...OA32) selected by the address input
(A) if the load input (L) or the set input (S) is 1. When the load input is set to 1, the input
(I) value is stored to the output only once. When the set input is set to 1, the input (I)
value is stored to the output every time the block is executed. The set input overrides
the load input.
If the reset input (R) is 1, all connected outputs are 0.
If the address input is 0, negative or exceeds the number of the outputs, all outputs
are 0.
Example:
S
L
R
1
0
0
0
0
0
0
1
0
1
0
0
1
1
0
1
1
1
The input data type is selected by the user.
Address input (A): DINT
Reset input (R): Boolean
Load input (L): Boolean
Set input (S): Boolean
Input (I): DINT, INT, REAL, REAL24, Boolean
The number of the output channels (1...32) is selected by the user.
Output (OA1...OA32): DINT, INT, REAL, REAL24, Boolean
0.68 µs (when two inputs are used) + 0.50 µs (for every additional input). When all
inputs are used, the execution time is 15.80 µs.
The output (OUT) is equal to the corresponding input (IN) if the activate input (ACT) is 1.
Otherwise the output is 0.
The input data type and the number of inputs (1...32) are selected by the user.
Activate input (ACT): Boolean
Input (IN1...IN32): INT, DINT, REAL, REAL24, Boolean
Output (OUT1...OUT32): INT, DINT, REAL, REAL24, Boolean
A
I
OA1
2
150
0
2
120
0
3
100
0
1
200
200
4
250
200
2
300
0
OA2
OA3
OA4
150
0
0
150
0
0
150
100
0
150
100
0
150
100
250
0
0
0

Advertisement

Table of Contents
loading

Table of Contents