14.3

Configure digital outputs

14.3.1

Digital output 1

Settings for digital output 1.
Details
The digital output 1 is controlled with the trigger selected in .
The following settings are possible for the digital output:
Inversion
Manual I/O control
Trigger
0x2634:002
Diagnostic parameters:
Display of the logic state of the trigger signal:
Display of the logic state of the digital output:
Inversion
The trigger signal of the digital output can be internally inverted logically.
Manual I/O control
The digital output can be overridden manually. After the function is activated, the actual val-
ues are "frozen". Afterwards, each digital output can be overwritten manually.
Setting:
Activation:
0x263C:001
Entering the manual value:
Parameter
Address
Name / setting range / [default setting]
0x2635:002
Inversion of digital outputs: Digital output 1
0 Not inverted
1 Inverted
0x4016:005
Digital output 1: Terminal state
• Read only
0 FALSE
1 TRUE
0x263C:001
Digital outputs internal control: Activation
0 Aus
1 Ein
0x263C:002
Digital outputs internal control: DO1 internal control
0 Aus
1 Ein
I/O extensions and control connections
0x60FE
0x2635:002
0
1
1
0x4016:005
0x263C:002
0x263C:001
0x4016:005
0
1
0x263C:002
Info
Inversion of digital output 1
Display of the logic state of output terminal X3/DO1.
Configure digital outputs
Digital output 1
X3
DO1
287