Process Input Data (Cia 402 Objects) - Lenze i950 Commissioning Manual

Servo inverters
Hide thumbs Also See for i950:
Table of Contents

Advertisement

11.3

Process input data (CiA 402 objects)

Parameter
Address
Name / setting range / [default setting]
0x2830
Inverter control word
0x0000 ... [0x0000] ... 0xFFFF
Bit 0 Flying restart completed
Bit 1 Block flying restart
Bit 4 Set load value
Bit 5 Select new actual position
Bit 6 Activate DC-injection braking or short-circuit
braking
Bit 10 Reserved
Bit 11 Reserved
0x2946:001
Speed limitation: Upper speed limit
-479999.999776482 ... [0] ... 479999.999776482 rpm
0x2946:002
Speed limitation: Lower speed limit
-479999.999776482 ... [0] ... 479999.999776482 rpm
0x6040
CiA: Controlword
0x0000 ... [0x0000] ... 0xFFFF
Bit 0 Switch on
Bit 1 Enable voltage
Bit 2 Quick stop
Bit 3 Enable operation
Bit 4 Operation mode specific
Bit 5 Operation mode specific
Bit 6 Operation mode specific
Bit 7 Fault reset
Bit 8 Halt
Bit 9 Operation mode specific
Bit 14 Release holding brake
0x6060
Modes of operation
0 No mode change/no mode assigned
2 CiA: Velocity mode
8 Cyclic sync position mode
9 Cyclic sync velocity mode
10 Cyclic sync torque mode
Configuring the torque control
Process input data (CiA 402 objects)
Info
The control word serves to influence the control functions.
This bit enables the control to report the acceptance of the recorded
speed to the "flying restart" function. Thus, the flying restart process is
completed.
TRUE: the flying restart process is blocked.
TRUE: set load value.
TRUE: define new actual position.
• Setting/shifting of Position actual value (0x6064) to Actual position
start value (0x2983) considering the set resolution (0x608F:001,
0x608F:002).
• Mode for setting the actual position: 0x2984)
DC-injection braking or short-circuit braking is activated via this bit.
Upper limit for the speed limitation.
• Setting is only effective with the selection "Upper speed limit [5]" in .
• Entry via keypad and Lenze Tools is in rpm!
• Via RPDO, the unit is vel. unit. and the scaling must be taken into
account.
• ± 480000 rpm = ±2 ^ 31 [n-unit]
Lower limit for speed limitation.
• Setting is only effective with the selection "Lower speed limit [5]" in .
• Entry via keypad and Lenze Tools is in rpm!
• Via RPDO, the unit is vel. unit. and the scaling must be taken into
account.
• ± 480000 rpm = ±2 ^ 31 [n-unit]
Mappable CiA 402 control word with bit assignment according to device
profile CiA 402.
1 = switch-on
1 = DC bus: Establish readiness for operation
0 = activate quick stop
1 = enable operation
0-1 edge = reset error
1 = stop motor (ramping down to frequency setpoint 0 Hz)
Operating mode dependent
1 = releasing holding brake manually
CAUTION!
• The manually triggered "Release holding brake" command has a direct
impact on the "Release holding brake [115]" trigger. Thus, the holding
brake can be manually released if the power section is switched off.
• The responsibility for a manual release of the holding brake has the
external trigger source for the "Release holding brake" command.
4Holding brake control
^ 229
Selection of the operating mode.
No operating mode (standstill)
CiA 402 velocity mode
4Operating mode "CiA 402 Velocity mode (vl)"
4Operating mode "CiA 402 Cyclic sync position mode (csp)"
4Operating mode "CiA 402 Cyclic sync velocity mode (csv)"
4Operating mode "CiA 402 Cyclic sync torque mode (cst)"
^ 148
^ 134
^ 153
^ 167