Configure speed control
Operating mode "CiA 402 Cyclic sync velocity mode (csv)"

Signal flow (V/f characteristic control)

10.3.3
Signal flow (V/f characteristic control)
Interpolation
Target velocity
Velocity actual value
156
Slip compensation
Speed
Current
Frequency
limitation
limitation
limitation
Oscillation
damping
DC-injection braking
Load
V/f
adjustment
characteristic
Current demand value
is limited
PWM
M
Current actual value
Voltage actual value
Output frequency
actual value