Delete Logbook Files; Activate Loaded Application; Uploading The Application - Lenze i950 Commissioning Manual

Servo inverters
Hide thumbs Also See for i950:
Table of Contents

Advertisement

17.8

Delete logbook files

The logbook files can be deleted with the parameter.
Parameter
Address
Name / setting range / [default setting]
0x2022:037
Device commands: Delete Logfiles
0 Off / ready
1 On / start
2 In progress
3 Action cancelled
4 No access
5 No access (Inverter disabled)
17.9

Activate loaded application

The loaded application can be activated with the
Parameter
Address
Name / setting range / [default setting]
0x2022:038
Device commands: Activate loaded application
0 Off / ready
1 On / start
2 In progress
3 Action cancelled
4 No access
5 No access (Inverter disabled)
17.10

Uploading the application

Parameter
Address
Name / setting range / [default setting]
0x2022:042
Device commands: Upload application
0 Off / ready
1 On / start
2 In progress
3 Action cancelled
4 No access
5 No access (Inverter disabled)
20 20%
40 40%
60 60%
80 80%
100 100%
101 No SD card connected
Info
Deletion of log files on the device that were exported in an earlier step
via
0x2022:036
(Export Logbook).
Only status feedback
Execute device command
Only status feedback
0x2022:038
parameter.
Info
Start of the application that is provided/downloaded by the »Applica-
tion Loader«.
Only status feedback
Execute device command
Only status feedback
Info
Only status feedback
Execute device command
Only status feedback
Device functions
Uploading the application
357

Hide quick links:

Advertisement

Table of Contents
loading