16.1.6.4

Switched on

This is the device state of the inverter after the
the
"Ready to switch
on" device state.
Process data monitoring is active.
Communication is possible.
The DC-bus voltage is available.
The inverter can be parameterised.
If the internal holding brake control (0x2820:001) is active in the inverter, the motor brake
is closed.
Operation is inhibited.
1
From all states
2
Power section inhibited (pulse inhibit)
3
Power section enabled
Bit pattern in the CiA 402 status word (0x6041)
Bit 15 ... 8
Bit 7
Reserved
Warning
(specific)
active
X
X
X = state is not relevant
"Switch
on" command has been triggered in
Bit 6
Bit 5
Operation
Quick stop
DC bus ready
inhibited
active
for operation
1
1
Configuring the network
Bit 4
Bit 3
Bit 2
Fault active
Operation
enabled
X
0
Device profile CiA 402
Device states
Bit 1
Bit 0
Switched on
Ready to
switch on
0
1
1
305