Device functions

Reset parameters to default

17.2
Reset parameters to default
Parameter
Address
Name / setting range / [default setting]
0x2022:001
Device commands: Load default settings
0 Off / ready
1 On / start
2 In progress
3 Action cancelled
4 No access
5 No access (Inverter disabled)
0x2022:039
Device commands: Load TA default settings
0 Off / ready
1 On / start
2 In progress
3 Action cancelled
4 No access
5 No access (Inverter disabled)
354
Info
1 ≡ reset all parameters in the RAM memory of the inverter to the
default setting that is stored in the inverter firmware.
• All parameter changes made by the user are lost during this process!
• It may take some seconds to execute the task. When the task has
been executed successfully, the value 0 is shown.
• Loading parameters has a direct effect on the cyclic communication:
The data exchange for control is interrupted and a communication
error is generated.
Only status feedback
Execute device command
Only status feedback
Only status feedback
Execute device command
Only status feedback