Configuring the feedback system
Second feedback system for the techology application

Resolver settings

12.2.2
Resolver settings
Resolvers with a number of pole pairs > 1 are not absolute value encoders.
Bit 10 in (Lenze status word 2) therefore remains set to "0".
The "distinguishable revolutions" specification in
Parameter
Address
Name / setting range / [default setting]
0x2822:029
Axis commands: Get load encoder/master encoder
characteristic (resolver)
0 Off / ready
1 On / start
2 In progress
3 Action cancelled
4 No access
5 No access (Inverter disabled)
0x2C53
Load encoder/master encoder resolver number of
pole pairs
1 ... [1] ... 1
• Setting can only be changed if the inverter is inhibi-
ted.
190
0x2C56
is also set to "0".
Info
Definition of the resolver characteristic for application feedback.
Only status feedback
Execute device command
Only status feedback
Setting of the number of pole pairs.