Sign In
Upload
Manuals
Brands
Lenze Manuals
DC Drives
i510 Series
Lenze i510 Series Manuals
Manuals and User Guides for Lenze i510 Series. We have
9
Lenze i510 Series manuals available for free PDF download: Commissioning, Service Manual, Operation Manual, Mounting And Switch-On Instructions, Operating Instructions Manual, Manual
Lenze i510 Series Commissioning (487 pages)
Inverter Cabinet
Brand:
Lenze
| Category:
Inverter
| Size: 6 MB
Table of Contents
Table of Contents
3
1 General Information
11
Read First, then Start
11
2 Safety Instructions
12
Basic Safety Measures
12
Residual Hazards
13
Application as Directed
13
3 Mechanical Installation
14
Dimensions
14
4 Electrical Installation
17
Important Notes
17
Mains Connection
18
1-Phase Mains Connection 230/240 V
18
Connection Plan
18
Fusing and Terminal Data
20
3-Phase Mains Connection 230/240
23
Connection Plan
23
Fusing and Terminal Data
24
3-Phase Mains Connection 400 V
26
Connection Plan
26
Fusing and Terminal Data
27
3-Phase Mains Connection
27
Connection Plan
30
Fusing and Terminal Data
31
Control Connections
33
Networks
33
Canopen/Modbus RTU
33
5 Commissioning
34
Important Notes
34
Operating Interfaces
35
Keypad
35
Engineering Tool "EASY Starter
36
Generate a Connection between Inverter and "EASY Starter
37
Parameter Setting
39
General Notes on Parameters
40
Basic Inverter Settings
41
Basic Motor Settings
44
Function Assignment of the Inputs and Outputs
45
Keypad Parameter List
48
Save Parameter Settings in the Memory Module
66
Save Parameter Settings with Keypad
66
Save Parameter Settings with "EASY Starter
66
6 Diagnostics and Fault Elimination
67
LED Status Display
67
Diagnostics Parameter
68
Logbook
69
Error History Buffer
70
Inverter Diagnostics
73
Network Diagnostics
77
Canopen Diagnostics
78
Modbus Diagnostics
80
Diagnostics of the Inputs and Outputs
81
Digital Inputs and Outputs
81
Analog Inputs and Outputs
82
Wireless-LAN Diagnostics
83
Setpoint Diagnostic
84
Process Controller Status
85
Sequencer Diagnostics
85
Device Identification
86
Device Overload Monitoring (I*T)
88
Heatsink Temperature Monitoring
88
Life-Diagnosis
89
Error Handling
90
Error Types
90
Error Configuration
91
Error Reset
91
Keypad Error Messages
91
Data Handling
92
7 Basic Setting
94
Mains Voltage
95
Control Source Selection
97
Selection of Setpoint Source
98
Keypad Setpoint Default Setting
101
Starting/Stopping Performance
103
Starting Performance
103
Stopping Performance
105
Frequency Limits and Ramp Times
106
Quick Stop
109
S-Shaped Ramps
111
Optical Device Identification
112
8 Motor Control
113
Motor Data
114
Manual Setting of the Motor Data
114
Motor Control Selection
115
V/F Characteristic Control (VFC)
116
Linear V/F Characteristic
117
Square-Law V/F Characteristic
118
User-Definable V/F Characteristic
119
V/F Characteristic Control - Energy-Saving (VFC Eco)
120
Sensorless Vector Control (SLVC)
122
Sensorless Control for Synchronous Motors (SL-PSM)
125
Stall Monitoring
128
Optimisation of Motor Control
129
V/F Voltage Boost
130
Skip Frequencies
131
Optimising the Stalling Behaviour
133
Slip Compensation
135
Oscillation Damping
137
Pole Position Identification Without Movement
138
Optimisation of the Control Loops
140
Options for Optimized Motor Tuning
143
Motor Selection from Motor Catalogue
144
Tuning of the Motor and the Speed Controller
145
Automatic Motor Identification (Energized)
146
Automatic Motor Calibration (Non-Energized)
147
Inverter Characteristics
147
Motor Equivalent Circuit Diagram Data
148
Motor Controller Settings
149
Current Controller
149
Field Controller
150
Field Weakening Controller
150
Field Weakening Controller (Advanced)
150
Imax Controller
151
Flying Restart Controller
152
SLVC Controller
152
Torque Control W/ Freq. Limit
153
Speed Controller
158
Motor Rotating Direction
159
Switching Frequency Changeover
160
Motor Protection
161
Motor Overload Monitoring (I²*T)
162
Current Limits
166
Overcurrent Monitoring
168
Motor Phase Failure Detection
169
Motor Speed Monitoring
170
Motor Torque Monitoring
170
9 Configuring the Network
172
General Network Settings
173
Predefined Process Data Words
191
Device Profile Cia
192
AC Drive Profile
193
Lenze LECOM Profile
194
Further Process Data
196
Parameter Access Monitoring (PAM)
202
Process Data Handling in Case of Error
203
Acyclic Data Exchange
203
Canopen
204
Introduction
204
Node Address Setting
205
Baud Rate Setting
205
Configure Device as Mini Master
206
Diagnostics
207
Emergency Telegram
208
Heartbeat Protocol
208
Process Data Objects
210
Data Mapping
215
Service Data Objects
218
Error Responses
219
Diagnostic Counter
220
LED Status Displays
221
Restart Communication
222
Short Setup
223
Modbus RTU
226
Introduction
226
Node Address Setting
227
Baud Rate Setting
227
Data Format Setting
228
Time-Out Monitoring
228
Diagnostics
228
Function Codes
231
Data Mapping
233
LED Status Displays
234
Restart Communication
235
Response Time Setting
235
Short Setup
236
10 Configuring the Process Controller
238
Basic Process Controller Settings
239
Process Controller - Idle State and Rinse Function
245
Process Controller Idle State
245
Process Controller Rinse Function
247
11 Additional Functions
248
Device Commands
249
Reset Parameters to Default
249
Saving/Loading the Parameter Settings
250
Device Commands for Parameter Change-Over
252
Delete Logbook
252
Keypad
253
Keypad Language Selection
253
Keypad Setpoint Increment
253
Keypad Scaling of Speed Display
253
Keypad Status Display
253
Keypad - Configuration of R/F and CTRL Buttons
254
Wireless LAN (WLAN)
257
WLAN LED Status Displays
257
WLAN Basic Settings
258
Resetting WLAN Settings to Default Setting
260
WLAN Access Point Mode
261
Establishing a Direct WLAN Connection between Smartphone and Inverter
262
Using the Smartphone as "Smart Keypad
263
Establishing a Direct WLAN Connection between Engineering PC and Inverter
264
WLAN Client Mode
266
DC Braking
268
Example 1: Automatic DC Braking When the Motor Is Started
270
Example 2: Automatic DC Braking When the Motor Is Stopped
271
Migration of Lenze Inverter Drives 8200/8400
273
Brake Energy Management
274
Stopping the Deceleration Ramp Function Generator
275
Inverter Motor Brake
276
Load Loss Detection
277
Access Protection
278
Write Access Protection
278
Write Access Protection in the "EASY Starter
280
Write Access Protection in the Keypad
283
Favorites
287
Accessing the "Favorites" with the Keypad
287
Favorites Parameter List (Default Setting)
288
Configuring the "Favorites
289
Parameter Change-Over
292
Example: Selective Control of Several Motors with One Inverter
295
Device Profile Cia 402
297
Holding Brake Control
300
Basic Setting
301
Automatic" Brake Mode (Automatic Operation)
302
Brake Holding Load
304
Brake Closing Level
306
Manual Release of the Holding Brake
308
Flying Restart Circuit
309
Timeout für Fault Reaction
311
Automatic Restart
312
Mains Failure Control
313
Activating the Mains Failure Control
315
Restart Protection
316
Fast Mains Recovery
316
Commissioning the Mains Failure Control
317
UPS Operation
318
Process Data
321
Position Counter
321
Firmware Download
322
Firmware Download with "EASY Starter (Firmware Loader)
322
Additive Voltage Impression
323
Example: Using the Function with a 400-V Inverter
324
12 Sequencer
325
Segment Configuration
327
Sequence Configuration
337
Sequencer Basic Settings
341
13 Flexible I/O Configuration
344
Control Source Change-Over
345
Example 1: Change-Over from Terminal Control to Keypad Control
348
Example 2: Change-Over from Terminal Control to Network Control
349
Start / Stop Motor
350
Example 1: Start/Stop (1 Signal) and Reversal
356
Example 2: Start Forward/Start Reverse/Stop (Edge-Controlled)
357
Example 3: Run Forward/Run Reverse/Stop (Status-Controlled)
359
Example 4: Quick Stop
361
Example 5: Jog Forward/Jog Reverse
362
Example 6: Enable Inverter
364
Setpoint Change-Over
365
Priority of the Setpoint Sources
367
Analog Input Setpoint Source
367
Keypad Setpoint Source
370
Network Setpoint Source
372
Setpoint Source of Preset Setpoints
373
Motor Potentiometer Setpoint Source (MOP)
378
Setpoint Source Segment Setpoints
382
Reset Error
384
Activating DC Braking Manually
386
Releasing Holding Brake Manually
388
Activating Ramp 2 Manually
390
Triggering a User-Defined Fault
392
Functions for Parameter Change-Over
393
Example 1: Activation Via Command (Only When Disabled)
395
Example 2: Activation Via Command (Immediately)
396
Example 3: Activation if the Selection Is Changed (Only if the Inverter Is Disabled)
397
Example 4: Activation if the Selection Is Changed (Immediately)
398
Process Controller Function Selection
399
Sequencer Control Functions
402
Frequency Threshold for "Frequency Threshold Exceeded" Trigger
407
Configuration of Digital Inputs
408
Configuration of Analog Inputs
409
Analog Input 1
409
Example 1: Input Range 0
411
Example 2: Input Range 0
411
13.14.1.3 Example 3: Error Detection
412
Analog Input 1
412
Configuration of Digital Outputs
415
Relay
415
Digital Output 1
418
Networdout1 Status Word
419
Configuration of Analog Outputs
422
Analog Output 1
422
Example 1: Output Voltage 0
424
Example 2: Output Voltage 2
424
14 Technical Data
425
Standards and Operating Conditions
425
Protection of Persons and Device Protection
425
EMC Data
425
Motor Connection
425
Environmental Conditions
426
Electrical Supply Conditions
426
1-Phase Mains Connection 230/240
427
Rated Data
427
3-Phase Mains Connection 230/240
428
Rated Data
428
3-Phase Mains Connection
428
3-Phase Mains Connection 480 V
429
Rated Data
429
Advertisement
Lenze i510 Series Service Manual (250 pages)
Cabinet 0.25 ... 22 kW
Brand:
Lenze
| Category:
DC Drives
| Size: 2 MB
Table of Contents
Analog Input
2
Table of Contents
3
1 General Information
8
Read First, then Start
8
2 Safety Instructions
9
Basic Safety Measures
9
3 Mounting
10
Mechanical Installation
10
4 Commissioning
13
Before Initial Switch-On
13
Operator-Process Interfaces
14
Establishing the Connection between the Inverter and »EASY Starter
15
Parameter Setting
16
General Notes on Parameters
17
Basic Inverter Settings
18
Basic Motor Settings
20
Function Assignment of the Inputs and Outputs
21
Keypad Parameter List
24
5 Diagnostics and Fault Elimination
42
LED Status Displays
42
Keypad Fault Display
43
Diagnostics
44
Logbook
45
Error History Buffer
46
Inverter Diagnostics
48
Network Diagnostics
53
Canopen Diagnostics
54
Modbus Diagnostics
57
Diagnostics of the Inputs and Outputs
57
Digital Inputs and Outputs
57
Analog Inputs and Outputs
58
Process Controller Status
60
Device Identification
60
Device Overload Monitoring (I*T)
61
Heatsink Temperature Monitoring
62
Diagnostics Timer
62
Short Overview of All Error Codes
63
6 Basic Setting
66
Mains Voltage
67
Control Source Selection
69
Selection of Setpoint Source
70
Keypad Setpoint Default Setting
71
Starting/Stopping Performance
72
Starting Performance
72
Stopping Performance
72
Frequency Limits and Ramp Times
73
Quick Stop
74
S-Shaped Ramps
75
Optical Device Identification
76
7 Motor Control
77
Motor Data
78
Motor Control Selection
81
V/F Characteristic Control
81
Linear V/F Characteristic
82
Square-Law V/F Characteristic
82
Sensorless Vector Control (SLVC)
82
Optimisation of Motor Control
84
Voltage Boost
84
Skip Frequencies
84
Optimising the Stalling Behaviour
86
Slip Compensation
87
Oscillation Damping
88
Optimisation of the Control Loops
89
Speed Controller
89
Imax Controller
89
Current Controller
89
Motor Rotating Direction
90
Switching Frequency Changeover
91
Motor Protection
92
Motor Overload Monitoring (I²*T)
92
Current Limits
93
Ultimate Motor Current
94
Motor Phase Failure Detection
94
Motor Speed Monitoring
95
8 Configuring the Network
96
General Network Settings
97
Device Profile Cia402
97
Predefined Process Data Words
104
AC Drive Profile
106
Lenze LECOM Profile
107
Further Process Data
108
Acyclic Data Exchange
111
Canopen
112
Canopen Introduction
112
Canopen Node Address
112
Canopen Baud Rate
113
Canopen Initialisation
113
Canopen Diagnostics
114
Canopen Emergency Telegram
115
Canopen Heartbeat Protocol
115
Canopen Process Data Objects
117
Canopen Data Mapping
120
Canopen Service Data Objects
122
Canopen Error Responses
124
Canopen Diagnostic Counter
125
Canopen LED Status Displays
126
Resetting the Canopen Interface
126
Modbus
127
Modbus Introduction
127
Modbus Node Address
127
Modbus Baud Rate
128
Modbus Data Format
128
Modbus Time-Out Monitoring
128
Modbus Diagnostics
128
Modbus Function Codes
131
Modbus Data Mapping
132
Modbus LED Status Displays
136
Reset Modbus Interface
136
Modbus Response Time
136
Short Setup of Modbus
137
9 Configuring the Process Controller
138
Basic Process Controller Settings
139
Process Controller - Idle State and Rinse Function
142
Process Controller Idle State
142
Process Controller Rinse Function
143
10 Additional Functions
144
Device Commands
145
Restoring the Lenze Settings
145
Saving/Loading the Parameter Settings
146
Device Commands for Parameter Change-Over
148
Initialising the Network Interface
149
Updating the Memory Module Data Format
149
Delete Logbook
150
Keypad
151
Keypad Language Selection
151
Keypad Setpoint Increment
151
Keypad Scaling of Speed Display
151
Keypad Status Display
152
DC Braking
153
Brake Energy Management
155
Stopping the Deceleration Ramp Function Generator
156
Inverter Motor Brake
157
Load Loss Detection
158
Access Protection
159
Write Access Protection
160
Favorites
162
Accessing the "Favorites" with the Keypad
162
Favorites Parameter List (Default Setting)
162
Configuring the "Favorites
163
Parameter Change-Over
167
Device Profile Cia402
177
Holding Brake Control
180
Flying Restart Function
182
Fault Configuration
183
Parameter for Engineering Tools
184
11 Flexible I/O Configuration
186
Control Source Change-Over
187
Controller Enable, Starting & Stopping, Reversal
188
Setpoint Change-Over
193
Priority of the Setpoint Sources
193
Analog Input Setpoint Source
193
Keypad Setpoint Source
194
Network Setpoint Source
194
Setpoint Source of Preset Setpoints
195
Motor Potentiometer Setpoint Source
198
Reset Error
201
Activating DC Braking Manually
202
Releasing Holding Brake Manually
203
Activating Ramp 2 Manually
204
Triggering a User-Defined Fault
205
Functions for Parameter Change-Over
206
Process Controller Function Selection
207
Frequency Threshold for "Frequency Threshold Exceeded" Trigger
209
Configuration of Digital Inputs
210
Configuration of Analog Inputs
211
Analog Input 1
211
Analog Input 2
213
Configuration of Digital Outputs
215
Relay
215
Digital Output 1
218
Networdout1 Status Word
218
Configuration of Analog Outputs
221
Analog Output 1
221
12 Technical Data
223
Standards and Operating Conditions
223
Rated Data
225
Connection to the 230 V System
225
Connection to the 400 V System
225
Lenze i510 Series Operation Manual (127 pages)
i500 inverter series cabinet
Brand:
Lenze
| Category:
Inverter
| Size: 2 MB
Table of Contents
Table of Contents
2
1 About this Manual
6
Purpose of this Manual
6
Storage Place
6
Reference to Other Documents
6
Copyright
6
Manufacturer's Address
6
Disclaimer of Liability
6
Parameter Description
7
2 Safety Information
8
Intended Use of Inverter
8
Examples of Unintended Use
8
Qualified Personnel
8
Signal Words and Symbols
8
Elements of a Safety Message
9
Warning Labels on Inverter
9
Basic Safety Measures
10
Electromagnetic Influences
11
Residual Hazards
11
3 Product Description
12
General
12
I500 Inverter Types
13
Overview
14
I510 Inverter Overview
14
I550 Inverter Overview
15
Typecode
16
4 Installation
17
Mechanical Installation
17
Electrical Installation
17
Wiring Overview I510
18
Wiring Overview I550
19
Control Wiring I510/I550
20
Default Control Setup
21
5 Commissioning
22
Set-Up Tools
22
Overview
22
Keypad
23
Easy Starter & USB Adapter
27
Commissioning Procedure
28
General Parameter Setup (Favorites)
29
Diagnostic
29
Basic Setup
29
Motor Control Modes
30
6 Function & Parameter Description
34
Parameter / Function Overview
34
Control Concept
36
Setpoint Structure / Operation Mode
36
Control Source
38
Control Examples
39
Rotation Direction
42
Group 1 - Diagnostics
43
General Diagnostic Data
43
Output Power
44
Output Energy
44
Analog Input 1 Diagnosis
44
Analog Input 2 Diagnosis
44
Analog Output 1 Value
44
Analog Output 2 Value
45
Heatsink Temperature
45
I/O Status
45
Process Controller Diagnosis
45
Motor Protection I2Xt
46
Control / Setpoint Source
46
Inverter Status
46
Device Utilization (Ixt)
47
Error Code
47
Timer / Counter
47
History Buffer
48
Device Data
48
Device Name
49
Device Module
49
Additional Status
49
Group 2 - Basic Setup
49
Default Control Source
49
Default Setpoint
50
Keypad Setpoints
51
Start and Stop Configuration
51
Start on Power up
52
Voltage Configuration
53
Min/Max Frequency
53
Acceleration / Deceleration
54
Quickstop Ramp Time (QSP)
55
Group 3 - Motor Control
56
Motor Control Mode
56
V/F: Curve Setting
59
V/F: Slip Compensation
60
V/F: Frequency Boost
60
V/F: Oscillation Damping
60
V/F: Override Point of Field Weakening
60
Rotation Restriction
61
Switching Frequency
61
Motor Thermal Overload (I2Xt)
62
Motor Temperature Sensor
63
Skip Frequency
64
Motor Parameter
65
Speed Limitation
66
Current Limitation
66
Torque Limitation
67
HTL Encoder Setup
67
Overspeed Monitoring
68
Overcurrent Monitoring
68
Group 4 - I/O Setup
69
Function List (Run/Stop/Start/Jog/Reverse)
69
Setpoint Selection
73
Motor Potentiometer
74
User Defined Faults
75
Digital Input Configuration
75
Frequency Threshold Setup
76
Digital Output Configuration
76
Analog Input Settings
78
Analog Output Settings
80
Preset Setpoints (Frequency, PID)
82
Group 5 - Fieldbus
83
Group 6 - PID Setup
83
PID Setup
83
PID Triggers
85
PID Setpoint Limits
85
PID Acceleration / Deceleration
85
PID Influence
86
PID Alarms
86
PID Sleep/Rinse Function
86
Group 7 - Auxiliary Functions
87
Device Functions (Factory Reset, Load/Store Parameter)
87
Keypad Setup
88
DC Brake Setup
88
Regenerative Energy Management
90
Loss of Load Detection
93
Motor Brake Control
93
Access Protection
93
Favorites Setup
94
Multiple Parameter Set Setup
94
7 Fieldbus
95
Canopen Quick Start
96
Modbus Quick Start
99
Profibus Quick Start
101
8 Drive Profile (Fieldbus)
103
Cia402
104
Control Word
104
Status Word
105
Speed Setpoint / Actual Speed
105
Legacy Lenze Format
106
Control Word C135
106
Status Word
107
Speed Setpoint / Actual Speed
108
AC Drive Profile
109
Control Word
109
Status Word
110
Speed Setpoint / Actual Speed
111
Netword Configuration
112
Networdin Configuration
113
Networdout Configuration
115
9 Troubleshooting
117
LED Status Display
117
CAN LED Status Display
117
Modbus LED Status Display
118
Profibus LED Status Display
118
Error History
119
Error History Keypad
119
Error History Easy Starter
120
Error Messages
120
10 Maintenance
125
Routine Inspections
125
Product Support
125
Advertisement
Lenze i510 Series Mounting And Switch-On Instructions (67 pages)
Brand:
Lenze
| Category:
DC Drives
| Size: 7 MB
Table of Contents
Table of Contents
3
About this Document
6
Further Documents
6
Notations and Conventions
7
Safety Instructions
8
Basic Safety Instructions
8
Application as Directed
9
Foreseeable Misuse
9
Residual Hazards
10
Product Information
12
Features
12
Identification of the Products
15
Mechanical Installation
16
Important Notes
16
Preparation
17
Dimensions
18
Electrical Installation
29
Important Notes
29
EMC-Compliant Installation
30
Connection According to UL
31
Important Notes
31
Fusing Data
32
Branch Circuit Protection (BCP)
32
Mains Connection
34
1-Phase Mains Connection 230/240 V
34
Connection Diagrams
34
Terminal Data
36
Fusing Data
37
3-Phase Mains Connection 230/240 V
38
Connection Diagrams
38
Terminal Data
40
Fusing Data
41
3-Phase Mains Connection 230/240 V "Light Duty
41
Connection Diagrams
41
Terminal Data
41
3-Phase Mains Connection 400 V
42
Connection Diagrams
42
Terminal Data
43
Fusing Data
44
3-Phase Mains Connection 400 V "Light Duty
44
Connection Diagrams
44
Terminal Data
44
3-Phase Mains Connection 480 V
45
Connection Diagrams
45
Terminal Data
46
Fusing Data
47
3-Phase Mains Connection 480 V "Light Duty
47
Connection Diagrams
47
Terminal Data
47
Connection to the IT System
48
Control Connections
49
Networks
50
Canopen/Modbus
50
Bacnet
51
Commissioning
52
Important Notes
52
Initial Switch-On and Functional Test
53
Technical Data
54
Standards and Operating Conditions
54
Conformities and Approvals
54
Protection of Persons and Device Protection
54
EMC Data
54
Motor Connection
55
Environmental Conditions
55
Electrical Supply Conditions
55
1-Phase Mains Connection 230/240 V
56
Rated Data
56
3-Phase Mains Connection 230/240 V
58
Rated Data
58
3-Phase Mains Connection 230/240 V "Light Duty
59
Rated Data
59
3-Phase Mains Connection 400 V
60
Rated Data
60
3-Phase Mains Connection 400 V "Light Duty
62
Rated Data
62
3-Phase Mains Connection 480 V Rated Data
63
3-Phase Mains Connection 480 V "Light Duty" Rated Data
65
Lenze i510 Series Operating Instructions Manual (32 pages)
IP20/NEMA 1
Brand:
Lenze
| Category:
Inverter
| Size: 2 MB
Table of Contents
Table of Contents
3
1 General Information
4
Target Group
4
Application as Directed
4
Device-Specific Standards and Directives
4
Relevant Standards and Directives for the Operator
4
Identification of the Products
5
2 Safety Instructions
5
Basic Safety Measures
5
Layout of Warning Notices
6
Residual Hazards
6
Technical Data
7
Standards and Operating Conditions
7
4 Mechanical Installation
8
Dimensions and Assembly
8
Cable Entries with Shield Support
9
5 Open and Close the Cover
9
6 Electrical Installation
10
General Overview of the Connections
10
EMC-Compliant Installation
10
Control Terminals
11
Relay Output
11
Canopen, Modbus RTU
11
1-Phase Mains Connection 120 V
12
1-Phase Mains Connection 230/240 V
13
3-Phase Mains Connection 230/240 V
14
3-Phase Mains Connection 400 V
15
3-Phase Mains Connection 480 V
16
Commissioning
17
Initial Switch-On
17
Keypad Module
17
Functions of the Keys
18
Example of Keypad Handling
18
Quick Commissioning - Terminal Control
18
Extended Terminal Control
19
Keypad Control
19
Commissioning with the EASY Starter
19
The most Important Parameters at a Glance
20
Group 0: Favorites
20
Group 2: Basic Setting
24
Group 3: Motor Control
24
Group 7: Additional Functions
24
8 Troubleshooting
25
Error Message
25
Reset Error
25
Error Codes
26
LED Status
28
Further Documents
28
10 Disposal
28
11 Glossary
28
Lenze i510 Series Operating Instructions Manual (28 pages)
Inverter i510-Cabinet 0.25 ... 15 kW
Brand:
Lenze
| Category:
Inverter
| Size: 1 MB
Table of Contents
Table of Contents
3
1 General Information
4
Target Group
4
Application as Directed
4
Device-Specific Standards and Directives
4
Relevant Standards and Directives for the Operator
4
Identification of the Products
5
2 Safety Instructions
5
Basic Safety Measures
5
Layout of Warning Notices
6
Residual Hazards
6
Standards and Operating Conditions
7
Connection to the IT System
7
Technical Data
7
4 Mechanical Installation
8
Dimensions and Assembly
8
5 Electrical Installation
9
General Overview of the Connections
9
EMC-Compliant Installation
9
Control Terminals
10
Relay Output
10
Single-Phase Mains Connection 230/240 V
11
Three-Phase Mains Connection 230/240 V
12
Three-Phase Mains Connection 400 V
13
Three-Phase Mains Connection 480 V
14
6 Initial Switch-On
15
Functions of the Keys
16
Example of the Keypad Handling
16
Quick Commissioning - Terminal Control
16
Extended Terminal Control
17
Keypad Control
17
Commissioning with the EASY Starter
17
The most Important Parameters at a Glance
18
Group 0: Favorites
18
Group 2: Basic Setting
22
Group 3: Motor Control
22
Group 7: Additional Functions
23
7 Commissioning
15
Keypad Module
15
8 Troubleshooting
24
Error Message
24
Reset Error
24
Error Codes
25
LED Status
27
9 Further Documents
27
10 Disposal
27
11 Glossary
27
Lenze i510 Series Manual (28 pages)
Teachware Application Case
Brand:
Lenze
| Category:
Inverter
| Size: 0 MB
Table of Contents
Deutsch
2
Table of Contents
2
1 Sicherheitshinweise
3
Grundlegende Sicherheitshinweise
3
Restgefahren
4
Bestimmungsgemäße Verwendung
4
Vorhersehbare Fehlanwendung
4
2 Technische Daten
5
Lieferumfang
5
Normen und Einsatzbedingungen
5
Bemessungsdaten
6
3 Inbetriebnahme
7
Vor dem Ersten Einschalten
7
Vorbereitung
8
Einschalten
8
Funktionsprüfung
8
Schaltsystem IO
9
Anschluss Externe Motoren
10
Verwendung des Encoders
11
Austausch der Control Unit (CU) am I550
11
4 Diagnose und Störungsbeseitigung
12
5 Wartung
12
6 Reparatur
13
7 Entsorgung
13
English
16
1 Safety Instructions
17
Basic Safety Instructions
17
Residual Hazards
18
Application as Directed
18
Foreseeable Misuse
18
2. Technical Data
19
Scope of Supply
19
Standards and Operating Conditions
19
Rating
20
3 Commissioning
21
Before Initial Switch-On
21
Preparation
22
Switch on
22
Functional Test
22
Switching System IO
23
Connection of External Motors
24
Using the Encoder
25
Replacement of the Control Unit (CU) on the I550
25
4 Troubleshooting and Fault Elimination
26
5 Maintenance
26
6 Repair
27
7 Disposal
27
Lenze i510 Series Operating Instructions Manual (43 pages)
cabinet frequency inverter
Brand:
Lenze
| Category:
Inverter
| Size: 1 MB
Table of Contents
General Information
2
Application as Directed
3
Identification of the Products
4
Basic Safety Instructions
6
Device Protection
6
Technical Data
8
Standards and Operating Conditions
8
Mechanical Installation
9
Electrical Installation
11
Connection Diagram
12
EMC-Compliant Installation
12
Initial Switch-On
22
Important Notes
23
Keypad-Module
23
Troubleshooting
37
Error Codes
38
Led Status
40
Lenze i510 Series Operating Instructions Manual (43 pages)
Cabinet frequency inverter
Brand:
Lenze
| Category:
Inverter
| Size: 3 MB
Table of Contents
General Information
2
Application as Directed
3
Identification of the Products
4
Basic Safety Instructions
6
Device Protection
6
Technical Data
8
Standards and Operating Conditions
8
Mechanical Installation
9
Electrical Installation
11
Connection Diagram
12
EMC-Compliant Installation
12
Initial Switch-On
22
Important Notes
23
Keypad-Module
23
Troubleshooting
37
Error Codes
38
Led Status
40
Advertisement
Related Products
Lenze i510 protec
Lenze I51AP175A
Lenze I51AP137D
Lenze I51AP175D
Lenze I51AP222D
Lenze I51AP230C
Lenze I51AE240F
Lenze I51AE255F
Lenze I51BE311F
Lenze I51AP137D00001K03S
Lenze Categories
DC Drives
Control Unit
Inverter
Engine
Controller
More Lenze Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL