Defining Control Sources; Source Of Quick Stop; Source Of Error Reset - Lenze i950 Commissioning Manual

Servo inverters
Hide thumbs Also See for i950:
Table of Contents

Advertisement

Technology application (TA) basic settings

Defining control sources

Source of error reset

6.3
Defining control sources
This chapter describes the selection of the control source for various control signals.

4Source of quick stop

^ 80
4Source of error reset
^ 80
4Source of digital output 1
4Source of monitoring signal
Settings in the »EASY Starter«:
Tab Settings - Parameter dialog Technology application
6.3.1
Source of quick stop
A quick stop can be requested via the control word or via a digital input. Use the Source for
quick stop parameter to select which input is used.
Parameter
Address
Name / setting range / [default setting]
0x5020:007
Application quick stop source
0 FALSE
1 TRUE
2 Digital input 1
3 Digital input 2
4 Digital input 3
5 Digital input 4
6.3.2
Source of error reset
An error can be reset via the fieldbus, the system bus or via a digital input. Use the Source for
error reset parameter to select which input is used.
Fig. 21: "Reset error" selection
Parameter
Address
Name / setting range / [default setting]
0x5020:008
Source of fault reset
0 FALSE
1 TRUE
2 Digital input 1
3 Digital input 2
4 Digital input 3
5 Digital input 4
80
^ 81
^ 82
40x5020:007
40x5020:008
0x5020:008
(Source reset error)
FALSE
TRUE
DigIn1
DigIn2
DigIn3
DigIn4
Info
Selection of the signal source for activating the quick stop.
Application
Info
Selection of digital inputs for resetting errors.