Commissioning
Operating interfaces
Engineering tool »EASY Starter«
4.2.1.1
Generate a connection between inverter and »EASY Starter«
For commissioning the inverter with the »EASY Starter«, a communication link with the inver-
ter is required. This can be established in a wired manner only.
Additional information on network configuration:
Further information on how to create a communication link via "PROFINET":
NET
^ 330
How to establish a communication to the inverter via the engineering port X16:
Preconditions
The functional test described in the mounting and switch-on instructions has been com-
pleted successfully (without any errors or faults).
The inverter is ready for operation (mains voltage is switched on).
Required accessories
Engineering PC with installed »EASY Starter«
Standard network cable
1. Plug the network cable into the engineering port X16 of the inverter.
2. Use the network cable to connect the inverter to the PC on which the »EASY Starter« is
installed.
3. Start the »EASY Starter«.
The "Add devices" dialog is shown.
4. Select the "Ethernet" connection.
5. Click the Insert button.
The »EASY Starter« searched for connected devices via the communication path selected.
When the connection has been established successfully, the inverter is displayed in the device
list. The inverter parameters can now be accessed via the tabs of the »EASY Starter«.
30
4Configure engineering port
4PROFI-
^ 288