16.1.6.2

Switch-on inhibited

This is the device state of the inverter after the device has been initialised successfully.
A change to this state also takes place when the EtherCAT bus is in "Operational" state or the
PDO communication via
0x2824
Process data monitoring is active.
Communication is possible.
The DC-bus voltage can be present.
The inverter can be parameterised.
If the internal holding brake control (0x2820:001) is active in the inverter, the motor brake
is closed.
Operation is inhibited.
1
From all states
2
Power section inhibited (pulse inhibit)
3
Power section enabled
Bit pattern in the CiA 402 status word (0x6041)
Bit 15 ... 8
Bit 7
Reserved
Warning
(specific)
active
X
X
X = state is not relevant
(Control selection) is deactivated.
Bit 6
Bit 5
Operation
Quick stop
DC bus ready
inhibited
active
for operation
1
X
Configuring the network
Bit 4
Bit 3
Bit 2
Fault active
Operation
enabled
X
0
Device profile CiA 402
Device states
Bit 1
Bit 0
Switched on
Ready to
switch on
0
0
0
303