Extended Settings For Identification; Load Standard Inverter Characteristic - Lenze i950 Commissioning Manual

Servo inverters
Hide thumbs Also See for i950:
Table of Contents

Advertisement

Configuring the motor control
Options for optimising the control loops
Inverter characteristic
Address
Name / setting range / [default setting]
0x2947:016
Inverter characteristic: Value y16
0.00 ... [0.00] ... 20.00 V
0x2947:017
Inverter characteristic: Value y17
0.00 ... [0.00] ... 20.00 V
In the event of an error
If an error occurs during the procedure or the pulse inhibit gets active (e.g. due to short-time
undervoltage), the procedure is terminated with inverter disable without the settings being
changed.
13.6.3.2

Extended settings for identification

For determining the characteristic, the current controller is automatically parameterised at
the start of the identification process. In case of motors with a very low stator leakage induc-
tance (< 1 mH), the automatic parameterisation can fail and the actual identification process
is aborted with an error message such as "short circuit".
For this case, it is possible to set the current controller manually via the
The
0x2DE0:001
parameter serves to select whether the current controller should be cal-
culated automatically or the values in
Parameter
Address
Name / setting range / [default setting]
0x2DE0:001
Current controller identification settings
0 Automatisch
1 Manuell (0x2942)
0x2DE0:003
Resolver - position detection dynamics
20 ... [100] ... 100 %
0x2DE0:004
Resolver - 8 kHz safety signal
0 Automatisch durch Gerätetyp
1 Ein
2 Aus
0x2DE0:007
Use measured voltage
0 Aus
1 Ein
13.6.3.3

Load standard inverter characteristic

If none or only one faulty inverter characteristic could be determined, a device-typical stand-
ard inverter characteristic can be loaded.
How to load the standard inverter characteristic:
1. Axis commands: load standard-Lh saturation characteristic
2. After completing the procedure, save the inverter characteristic set in in the inverter.
The »EASY Starter« serves to save the parameter setting of the inverter as parameter file
(*.gdc).
4Saving the parameter settings
Parameter
Address
Name / setting range / [default setting]
0x2822:022
Axis commands: Load default inverter characteristic
0 Off/Ready
1 On/Start
2 In process
3 Action cancelled
4 No access
5 No access (controller inhibit)
238
Info
0x2942
are effective.
Info
Whether the current controller shall be adapted automatically for the
identification or set manually, is selected via:
0x2942:001
0x2942:002
Setting of the dynamics for the resolver evaluation.
• 100% ≡ max. dynamics
• <100% ≡ reduced dynamics
Usually ,the Der 8-kHz carrier frequency is only activated for the safety
version. This parameter can also be used to switch it on and off.
Activation of voltage measurement.
Only for devices for which voltage measurement is possible.
0x2822:022
Info
Parameters for interaction with engineering tools.
Obtain Hiperface information from the encoder for application feedback.
0x2942
parameter.
(Gain)
(Reset time)
= start 1.