Virtual Mode - Lenze i950 Commissioning Manual

Servo inverters
Hide thumbs Also See for i950:
Table of Contents

Advertisement

Technology application (TA) basic settings
Kinematic settings

Virtual mode

6.1.7
Virtual mode
The application can be tested without a connected motor. For this purpose, the setpoint selec-
tion for the drive can be interrupted.
When the virtual mode is active, the setpoints generated in the application are not transmit-
ted to the drive. The actual values (e. g. position and velocity) are generated from the set-
points.
The kinematic parameters do not have any influence in the virtual mode. Only the parameters
travel range and cycle length are used for the machine measuring system.
Machine measuring system parameters
Travel range
40x500A:030
Cycle length
40x500B:031
For diagnostic purposes, an active virtual mode is displayed in the Status word parameter.
Bit 0
40x500A:005
Parameter
Address
Name / setting range / [default setting]
0x500A:029
Virtual mode
• Setting can only be changed if the inverter is inhibi-
ted.
false Inactive
true Active